Navigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria. Issue 1 (6th September 2013)
- Record Type:
- Journal Article
- Title:
- Navigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria. Issue 1 (6th September 2013)
- Main Title:
- Navigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria
- Authors:
- Schmidt, Ehud J.
Fung, Maggie M.
Ciris, Pelin Aksit
Song, Ting
Shankaranarayanan, Ajit
Holmvang, Godtfred
Gupta, Sandeep N.
Chaput, Miguel
Levine, Robert A.
Ruskin, Jeremy
Reddy, Vivek Y.
D'avila, Andre
Aletras, Anthony H.
Danik, Stephan B. - Abstract:
- Abstract: Aims: Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). Methods and results: A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 × 1.0 × 4 mm 3 resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 ± 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. Conclusions: Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoringAbstract: Aims: Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). Methods and results: A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 × 1.0 × 4 mm 3 resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 ± 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. Conclusions: Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoring of atrial ablation lesions. … (more)
- Is Part Of:
- Europace. Volume 16:Issue 1(2014:Jan.)
- Journal:
- Europace
- Issue:
- Volume 16:Issue 1(2014:Jan.)
- Issue Display:
- Volume 16, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2014-0016-0001-0000
- Page Start:
- 133
- Page End:
- 141
- Publication Date:
- 2013-09-06
- Subjects:
- Magnetic resonance imaging ablation -- Atrial fibrillation -- Porcine model
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eut229 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25665.xml