Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial. (2nd September 2015)
- Record Type:
- Journal Article
- Title:
- Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial. (2nd September 2015)
- Main Title:
- Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial
- Authors:
- Kuramitsu, Shoichi
Kazuno, Yoshio
Sonoda, Shinjo
Domei, Takenori
Jinnouchi, Hiroyuki
Yamaji, Kyohei
Soga, Yoshimitsu
Shirai, Shinichi
Ando, Kenji
Saito, Shigeru - Abstract:
- Abstract: Aims: The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomography (OCT). Methods and results: A total of 36 patients participated in the CENTURY II trial in our institution and were randomly assigned to BP-SES ( n = 15) and PP-EES ( n = 21). Of these, 27 patients (13 BP-SES and 14 PP-EES) underwent OCT at 9-month follow-up. Tissue coverage and apposition were assessed on each strut, and the results in both groups were compared using multilevel logistic or linear regression models with random effects at three levels: patient, lesion, and struts. A total of 6450 struts (BP-SES, n = 2951; PP-EES, n = 3499) were analysed. Thirty and 79 uncovered struts (1.02 and 2.26%, P = 0.35), and 3 and 4 malapposed struts (0.10 and 0.11%, P = 0.94) were found in BP-SES and PP-EES groups, respectively. Mean neointimal thickness did not significantly differ between both groups (110 ± 10 vs. 93 ± 10 µm, P = 0.22). No significant differences in per cent neointimal volume obstruction (13.2 ± 4.6 vs. 10.5 ± 4.9%, P = 0.14) or other areas-volumetric parameters were detected between both groups. Conclusion: BP-SES shows an excellent vascular healing response atAbstract: Aims: The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomography (OCT). Methods and results: A total of 36 patients participated in the CENTURY II trial in our institution and were randomly assigned to BP-SES ( n = 15) and PP-EES ( n = 21). Of these, 27 patients (13 BP-SES and 14 PP-EES) underwent OCT at 9-month follow-up. Tissue coverage and apposition were assessed on each strut, and the results in both groups were compared using multilevel logistic or linear regression models with random effects at three levels: patient, lesion, and struts. A total of 6450 struts (BP-SES, n = 2951; PP-EES, n = 3499) were analysed. Thirty and 79 uncovered struts (1.02 and 2.26%, P = 0.35), and 3 and 4 malapposed struts (0.10 and 0.11%, P = 0.94) were found in BP-SES and PP-EES groups, respectively. Mean neointimal thickness did not significantly differ between both groups (110 ± 10 vs. 93 ± 10 µm, P = 0.22). No significant differences in per cent neointimal volume obstruction (13.2 ± 4.6 vs. 10.5 ± 4.9%, P = 0.14) or other areas-volumetric parameters were detected between both groups. Conclusion: BP-SES shows an excellent vascular healing response at 9-month follow-up, which is similar to PP-EES. … (more)
- Is Part Of:
- European heart journal. Volume 17:Number 1(2016:Jan.)
- Journal:
- European heart journal
- Issue:
- Volume 17:Number 1(2016:Jan.)
- Issue Display:
- Volume 17, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2016-0017-0001-0000
- Page Start:
- 34
- Page End:
- 40
- Publication Date:
- 2015-09-02
- Subjects:
- Bioresorbable polymer -- Sirolimus-eluting stent -- Optical coherence tomography -- Coronary artery disease
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jev203 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25652.xml