Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques. (19th July 2018)
- Record Type:
- Journal Article
- Title:
- Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques. (19th July 2018)
- Main Title:
- Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques
- Authors:
- Loger, Klaas
Lutter, Georg
Huenges, Katharina
Frank, Derk
Groß, Justus
Cremer, Jochen
Attmann, Tim
Morlock, Michael
Pokorny, Saskia - Abstract:
- Abstract: OBJECTIVES: Transcatheter mitral valved stent implantation provides an off-pump treatment option for mitral valve regurgitation, especially for secondary mitral valve regurgitation. The aim of this study was to evaluate novel fixation strategies: direct fixation (SUPRA) and subvalvular fixation (sub-VALV) to successfully implement alternative fixation methods at the mitral annulus and to reduce radial stent and apical tether forces. METHODS: Specific concepts were developed for the supra-annular hook-shaped fixation (SUPRA) and the subvalvular fixation (sub-VALV). These prototypes were compared with the sole apical tether fixation (AP) methods. Thirty-three pigs underwent mitral valved stent implantation accompanied by standardized transoesophageal echocardiographic and haemodynamic evaluation of heart function and the stent performance 1 h after implantation. Additionally, animals were followed up for 3 months. RESULTS: Secure deployment and correct positioning with low transvalvular gradients were achieved in all cases with mitral valved stent implantation. Nevertheless, 2 pigs died due to rhythm disturbances during dissection and pre-transcatheter mitral valve implantation. Paravalvular leakages were trace or less in prototypes with supra-annular fixation and sole apical fixation. In contrast, moderate paravalvular leakages were observed in the sub-VALV group ( P < 0.001). In addition, the effect of a specific stent design on heart function was demonstrated: anAbstract: OBJECTIVES: Transcatheter mitral valved stent implantation provides an off-pump treatment option for mitral valve regurgitation, especially for secondary mitral valve regurgitation. The aim of this study was to evaluate novel fixation strategies: direct fixation (SUPRA) and subvalvular fixation (sub-VALV) to successfully implement alternative fixation methods at the mitral annulus and to reduce radial stent and apical tether forces. METHODS: Specific concepts were developed for the supra-annular hook-shaped fixation (SUPRA) and the subvalvular fixation (sub-VALV). These prototypes were compared with the sole apical tether fixation (AP) methods. Thirty-three pigs underwent mitral valved stent implantation accompanied by standardized transoesophageal echocardiographic and haemodynamic evaluation of heart function and the stent performance 1 h after implantation. Additionally, animals were followed up for 3 months. RESULTS: Secure deployment and correct positioning with low transvalvular gradients were achieved in all cases with mitral valved stent implantation. Nevertheless, 2 pigs died due to rhythm disturbances during dissection and pre-transcatheter mitral valve implantation. Paravalvular leakages were trace or less in prototypes with supra-annular fixation and sole apical fixation. In contrast, moderate paravalvular leakages were observed in the sub-VALV group ( P < 0.001). In addition, the effect of a specific stent design on heart function was demonstrated: an increased rate of ischaemia and arrhythmia ( P = 0.037) and a small left ventricular ejection fraction reduction ( P < 0.05) were observed in the group with subvalvular fixation. In all but 1 case, gross evaluation demonstrated a good ingrowth of the valved stents of between 36% and 100% tissue coverage after a follow-up of 1 month or longer. CONCLUSIONS: The low degree of paravalvular leakages in the supra-annular and apical fixation groups and the normal longitudinal function highlight the good alignment of these new mitral valved stent designs within the native anatomy. The novel, hook-shaped, supra-annular fixation elements were well tolerated in the hearts resulting in excellent health of the animals at long-term follow-up times of up to 3 months. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 54:Number 6(2018)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 54:Number 6(2018)
- Issue Display:
- Volume 54, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 54
- Issue:
- 6
- Issue Sort Value:
- 2018-0054-0006-0000
- Page Start:
- 1013
- Page End:
- 1021
- Publication Date:
- 2018-07-19
- Subjects:
- Transcatheter -- Mitral valve -- Stent -- Fixation -- Percutaneous -- Transapical
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezy188 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25659.xml