Adding a masonry floor on top of a reinforced concrete high building in a seismic area. Issue 1 (March 2020)
- Record Type:
- Journal Article
- Title:
- Adding a masonry floor on top of a reinforced concrete high building in a seismic area. Issue 1 (March 2020)
- Main Title:
- Adding a masonry floor on top of a reinforced concrete high building in a seismic area
- Authors:
- Constantinescu, S
- Abstract:
- Abstract: The paper studies the influence of adding an aerated autoclaved concrete (AAC) masonry walls story above a reinforced concrete structure of a high building. This structure is situated in a high seismic area (0.30 g, where g is the gravity acceleration) in Bucharest, Romania. The new story will be lightweight because of the AAC. It is necessary to establish if the existing structure can bare the new story gravity loads and to determine the new building's seismic behaviour. It is also determined if the new AAC masonry walls can bare the seismic loads they are to be subjected to. Both elastic and plastic analysis are present in the study.
- Is Part Of:
- IOP conference series. Volume 789:Issue 1(2020)
- Journal:
- IOP conference series
- Issue:
- Volume 789:Issue 1(2020)
- Issue Display:
- Volume 789, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 789
- Issue:
- 1
- Issue Sort Value:
- 2020-0789-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Materials science -- Periodicals
620.1105 - Journal URLs:
- http://iopscience.iop.org/1757-899X ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1757-899X/789/1/012013 ↗
- Languages:
- English
- ISSNs:
- 1757-8981
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25633.xml