Validity and reliability of short‐term heart‐rate variability from disposable electrocardiography leads. Issue 1 (8th December 2022)
- Record Type:
- Journal Article
- Title:
- Validity and reliability of short‐term heart‐rate variability from disposable electrocardiography leads. Issue 1 (8th December 2022)
- Main Title:
- Validity and reliability of short‐term heart‐rate variability from disposable electrocardiography leads
- Authors:
- Okwose, Nduka C.
Russell, Sophie L.
Rahman, Mushidur
Steward, Charles J.
Harwood, Amy E.
McGregor, Gordon
Ninkovic, Srdjan
Maddock, Helen
Banerjee, Prithwish
Jakovljevic, Djordje G. - Abstract:
- Abstract: Background and Aims: Single‐use electrocardiography (ECG) leads have been developed to reduce healthcare‐associated infection. This study compared the validity and reliability of short‐term heart rate variability (HRV) obtained from single‐use disposable ECG leads. Methods: Thirty healthy subjects (33 ± 10 years; 9 females) underwent 5‐min resting HRV assessments using disposable (single use) ECG cable and wire system (Kendall DL™ Cardinal Health) and a standard, reusable ECG leads (CardioExpress, Spacelabs Healthcare). Results: Intraclass correlation coefficient (ICC) with 95% confidence interval (CI) between disposable and reusable ECG leads was for the time domain [R‐R interval (ms); 0.99 (0.91, 1.00)], the root mean square of successive normal R‐R interval differences (RMSSD) (ms); 0.91 (0.76, 0.96), the SD of normal‐to‐normal R‐R intervals (SDNN) (ms); 0.91 (0.68, 0.97) and frequency domain [low‐frequency (LF) normalized units (nu); 0.90 (0.79, 0.95), high frequency (HF) nu; 0.91 (0.80, 0.96), LF power (ms 2 ); 0.89 (0.62, 0.96), HF power (ms 2 ); 0.90 (0.72, 0.96)] variables. The mean difference and upper and lower limits of agreement between disposable and reusable leads for time‐ and frequency‐domain variables were acceptable. Analysis of repeated measures using disposable leads demonstrated excellent reproducibility (ICC 95% CI) for R‐R interval (ms); 0.93 (0.85, 0.97), RMSSD (ms); 0.93 (0.85, 0.97), SDNN (ms); 0.88 (0.75, 0.95), LF power (ms 2 ); 0.87Abstract: Background and Aims: Single‐use electrocardiography (ECG) leads have been developed to reduce healthcare‐associated infection. This study compared the validity and reliability of short‐term heart rate variability (HRV) obtained from single‐use disposable ECG leads. Methods: Thirty healthy subjects (33 ± 10 years; 9 females) underwent 5‐min resting HRV assessments using disposable (single use) ECG cable and wire system (Kendall DL™ Cardinal Health) and a standard, reusable ECG leads (CardioExpress, Spacelabs Healthcare). Results: Intraclass correlation coefficient (ICC) with 95% confidence interval (CI) between disposable and reusable ECG leads was for the time domain [R‐R interval (ms); 0.99 (0.91, 1.00)], the root mean square of successive normal R‐R interval differences (RMSSD) (ms); 0.91 (0.76, 0.96), the SD of normal‐to‐normal R‐R intervals (SDNN) (ms); 0.91 (0.68, 0.97) and frequency domain [low‐frequency (LF) normalized units (nu); 0.90 (0.79, 0.95), high frequency (HF) nu; 0.91 (0.80, 0.96), LF power (ms 2 ); 0.89 (0.62, 0.96), HF power (ms 2 ); 0.90 (0.72, 0.96)] variables. The mean difference and upper and lower limits of agreement between disposable and reusable leads for time‐ and frequency‐domain variables were acceptable. Analysis of repeated measures using disposable leads demonstrated excellent reproducibility (ICC 95% CI) for R‐R interval (ms); 0.93 (0.85, 0.97), RMSSD (ms); 0.93 (0.85, 0.97), SDNN (ms); 0.88 (0.75, 0.95), LF power (ms 2 ); 0.87 (0.72, 0.94), and HF power (ms 2 ); 0.88 (0.73, 0.94) with coefficient of variation ranging from 2.2% to 5% ( p > 0.37 for all variables). Conclusion: Single‐use Kendall DL™ ECG leads demonstrate a valid and reproducible tool for the assessment of HRV. … (more)
- Is Part Of:
- Health science reports. Volume 6:Issue 1(2023)
- Journal:
- Health science reports
- Issue:
- Volume 6:Issue 1(2023)
- Issue Display:
- Volume 6, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 6
- Issue:
- 1
- Issue Sort Value:
- 2023-0006-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-12-08
- Subjects:
- disposable leads -- ECG -- heart rate variability -- reproducibility -- validity
610 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/hsr2.984 ↗
- Languages:
- English
- ISSNs:
- 2398-8835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25645.xml