Late Clinical and Hemodynamic Outcomes in patients with degenerated bioprosthetic aortic valves undergoing transcatheter valve-in-valve implantation. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Late Clinical and Hemodynamic Outcomes in patients with degenerated bioprosthetic aortic valves undergoing transcatheter valve-in-valve implantation. (14th October 2021)
- Main Title:
- Late Clinical and Hemodynamic Outcomes in patients with degenerated bioprosthetic aortic valves undergoing transcatheter valve-in-valve implantation
- Authors:
- Abushouk, A I
Abdelfattah, O
Saad, A
Gad, M M
Reed, G W
Puri, R
Yun, J
Vargo, P R
Weiss, A
Burns, D
Popovic, Z
Harb, S C
Krishnaswamy, A
Svensson, L G
Kapadia, S R - Abstract:
- Abstract: Background: Clinical studies have shown promising early outcomes for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI); however, the late outcomes of this procedure remain under-investigated. Purpose: We performed the present analysis to assess the late clinical and hemodynamic outcomes of ViV-TAVI in patients with degenerated bioprosthetic aortic valves. Methods: A comprehensive chart review was performed for eligible patients to retrieve data on procedural characteristics, admission details following the procedure, and echocardiographic parameters. Clinical outcomes included all-cause mortality, heart failure hospitalization and structural valve deterioration (SVD), as defined by VARC-II criteria, up to 5 years of follow-up. To assess the trends in mean and peak transvalvular gradients, data from the follow-up echocardiographic reports were analyzed using Syngo Dynamics imaging software. Results: A total of 188 patients were included with a mean age of 75.8±10.4 years. Balloon- and self-expandable valves were used in 155 (82.4%) and 33 (17.6%) patients, respectively. At 30 days, 3 (1.6%) patients died and 8 (4.2%) required hospitalization for heart failure, while at 5 years, both events were recorded in 29 (15.4%) and 37 (19.7) patients, respectively. Kaplan-Meier survival analysis showed that patients with smaller surgical valves (internal diameter ≤21 mm) had a significantly higher mortality rate (log-rank p=0.021) than those with larger valves;Abstract: Background: Clinical studies have shown promising early outcomes for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI); however, the late outcomes of this procedure remain under-investigated. Purpose: We performed the present analysis to assess the late clinical and hemodynamic outcomes of ViV-TAVI in patients with degenerated bioprosthetic aortic valves. Methods: A comprehensive chart review was performed for eligible patients to retrieve data on procedural characteristics, admission details following the procedure, and echocardiographic parameters. Clinical outcomes included all-cause mortality, heart failure hospitalization and structural valve deterioration (SVD), as defined by VARC-II criteria, up to 5 years of follow-up. To assess the trends in mean and peak transvalvular gradients, data from the follow-up echocardiographic reports were analyzed using Syngo Dynamics imaging software. Results: A total of 188 patients were included with a mean age of 75.8±10.4 years. Balloon- and self-expandable valves were used in 155 (82.4%) and 33 (17.6%) patients, respectively. At 30 days, 3 (1.6%) patients died and 8 (4.2%) required hospitalization for heart failure, while at 5 years, both events were recorded in 29 (15.4%) and 37 (19.7) patients, respectively. Kaplan-Meier survival analysis showed that patients with smaller surgical valves (internal diameter ≤21 mm) had a significantly higher mortality rate (log-rank p=0.021) than those with larger valves; however, no significant difference (log-rank p=0.59) was detected between different transcatheter valves (self vs. balloon-expandable). Three patients underwent re-intervention, performed via a transcatheter approach. Further, assessment of follow-up echocardiographic reports revealed 9 (4.8%) cases of SVD, as well as stable mean (16.3±6.9 at discharge and 16.9±11.3) and peak (30.3±12.1 at discharge and 30.7±18.4 at 5 years) transvalvular gradients. No difference (p>0.05) was observed based on transcatheter valve type or surgical valve internal diameter in terms of mean and peak transvalvular gradients throughout the follow-up period. Conclusion: The present study showed good clinical outcomes among patients undergoing VIV-TAVI, with stable VIV performance over a five-year period. Future long-term studies are warranted to analyze the predictors of outcomes following ViV-TAVI and explore the role of this treatment option in the life-long management of aortic stenosis. FUNDunding Acknowledgement: Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): Jennifer and Robert McNeil Donation to the Heart, Thoracic, and Vascular Institute at Cleveland Clinic. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Aortic Valve Intervention
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.2200 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: