Echo-guided LVAD speed optimization for exercise maximization. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Echo-guided LVAD speed optimization for exercise maximization. (14th October 2021)
- Main Title:
- Echo-guided LVAD speed optimization for exercise maximization
- Authors:
- Stapor, M
Pilat, A
Gackowski, A
Gorkiewicz-Kot, I
Kleczynski, P
Zmudka, K
Legutko, J
Kapelak, B
Wierzbicki, K - Abstract:
- Abstract: Background: Continuous-flow left ventricular assist devices (LVAD) are becoming a destination therapy in patients with end-stage left ventricular dysfunction and a competitive method for heart transplantation. Current generation pumps operate with a fixed rotation speed and do not have the automatic speed adjustment capability. However, it was shown that acceleration of the pump speed during stress test increases the maximum exercise tolerance. Purpose: The study aimed to evaluate the concept of dynamic pump speed optimization based on the echocardiographic assessment of aortic valve opening (AVO) during the cardiopulmonary exercise test (CPET). Methods: Patients with implanted third-generation centrifugal continuous-flow LVAD's with hydrodynamic bearing were prospectively included. Two CPET's were performed after resting speed optimization. The first one with maintained baseline pump speed settings, and the second one with gradually increased speed depending on live echocardiographic imaging. The sequence of tests was random. Results: Exercise AVO was apparent in all 22 included patients. The resting pump speed was 2691 RPM and incremented on average by 566 RPM (20%). Pump power and flow raised from 5.6 to 9.8 Watts (p<0.0001) and from 5.8 to 7.3 l/min (p<0.0001), respectively. Peak VO2 increased from 11.1 to 12.8 ml/kg/min (p=0.0003) and maximum workload from 1.1 to 1.2 W/kg (p=0.03). The Borg scale exertion level decreased from 15.2 to 13.5 (p=0.0049). There wasAbstract: Background: Continuous-flow left ventricular assist devices (LVAD) are becoming a destination therapy in patients with end-stage left ventricular dysfunction and a competitive method for heart transplantation. Current generation pumps operate with a fixed rotation speed and do not have the automatic speed adjustment capability. However, it was shown that acceleration of the pump speed during stress test increases the maximum exercise tolerance. Purpose: The study aimed to evaluate the concept of dynamic pump speed optimization based on the echocardiographic assessment of aortic valve opening (AVO) during the cardiopulmonary exercise test (CPET). Methods: Patients with implanted third-generation centrifugal continuous-flow LVAD's with hydrodynamic bearing were prospectively included. Two CPET's were performed after resting speed optimization. The first one with maintained baseline pump speed settings, and the second one with gradually increased speed depending on live echocardiographic imaging. The sequence of tests was random. Results: Exercise AVO was apparent in all 22 included patients. The resting pump speed was 2691 RPM and incremented on average by 566 RPM (20%). Pump power and flow raised from 5.6 to 9.8 Watts (p<0.0001) and from 5.8 to 7.3 l/min (p<0.0001), respectively. Peak VO2 increased from 11.1 to 12.8 ml/kg/min (p=0.0003) and maximum workload from 1.1 to 1.2 W/kg (p=0.03). The Borg scale exertion level decreased from 15.2 to 13.5 (p=0.0049). There was a visible trend towards longer exercise time (36s) but no statistical significance was achieved (p=0.1). Conclusion: Ultrasonographic AVO analysis is possible during CPET's in patients supported with LVAD. Dynamic echo-guided pump speed adjustment based on the AVO improves exercise tolerance, augments peak VO2 consumption and maximal workload. An automatic speed adjustment in the next generations of LVAD controllers might improve functional capacity and requires further basic, technological and clinical research. Funding Acknowledgement: Type of funding sources: Other. Main funding source(s): 1. Cor Aegrum Foundation of Cardiac Surgery Development in Cracow2. Medtronic Poland Sp. z o.o. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Ventricular Assist Devices
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0947 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25630.xml