Assessment of mitral valve area by 3D planimetry after percutaneous mitral valve repair. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Assessment of mitral valve area by 3D planimetry after percutaneous mitral valve repair. (14th October 2021)
- Main Title:
- Assessment of mitral valve area by 3D planimetry after percutaneous mitral valve repair
- Authors:
- Gordillo, X
Pozo Osinalde, E
Salinas Gallegos, A
Jimenez Quevedo, P
Marcos-Alberca, P
Mahia, P
Tirado, G
Perez De Isla, L
Macaya, C
Perez-Villacastin, J
Fernandez-Ortiz, A
Nombela-Franco, L
De Agustin, J A - Abstract:
- Abstract: Background: Percutaneous mitral valve (MV) repair has become an effective therapeutic alternative to MV surgery in high-risk surgical patients with severe MR. Persistent pulmonary hypertension after mitral valve replacement has shown an increased risk of morbidity and mortality. Improvement of pulmonary systolic arterial pressure (PSAP) post-MitraClip has been reported, however relative mitral stenosis may hamper this benefit. Few data is available regarding the best echocardiographic parameter to determine mitral stenosis after the procedure. Purpose: To evaluate the correlation between the residual mitral valve area (MVA) by 3D planimetry, the pressure half time (PHT) and the transmitral gradient after percutaneous edge-to-edge mitral repair. Methods: This is a single-center, retrospective study. We enrolled 88 consecutive patients who underwent a percutaneous MV repair with the MitraClip system between 2010 and 2020 at our tertiary university hospital, with eligibility evaluation by transesophageal echocardiogram (TEE). All patients had moderate to severe (3+) or severe (4+) primary or secondary MR. Results: The mean age was 76.2±10.4 years and 64.8% of the patients were male. Above 88% of patients were in New York Heart Association class III/IV. Baseline 3D planimetry MVA was 5.3±1.4cm 2 and mean gradient pre-implantation was 1.8±0.8mmHg. After the procedure, MVA reduced to 2.9±0.8cm 2 and mean gradient was 2.8±1.4mmHg. Both 3D planimetry and mean gradient wereAbstract: Background: Percutaneous mitral valve (MV) repair has become an effective therapeutic alternative to MV surgery in high-risk surgical patients with severe MR. Persistent pulmonary hypertension after mitral valve replacement has shown an increased risk of morbidity and mortality. Improvement of pulmonary systolic arterial pressure (PSAP) post-MitraClip has been reported, however relative mitral stenosis may hamper this benefit. Few data is available regarding the best echocardiographic parameter to determine mitral stenosis after the procedure. Purpose: To evaluate the correlation between the residual mitral valve area (MVA) by 3D planimetry, the pressure half time (PHT) and the transmitral gradient after percutaneous edge-to-edge mitral repair. Methods: This is a single-center, retrospective study. We enrolled 88 consecutive patients who underwent a percutaneous MV repair with the MitraClip system between 2010 and 2020 at our tertiary university hospital, with eligibility evaluation by transesophageal echocardiogram (TEE). All patients had moderate to severe (3+) or severe (4+) primary or secondary MR. Results: The mean age was 76.2±10.4 years and 64.8% of the patients were male. Above 88% of patients were in New York Heart Association class III/IV. Baseline 3D planimetry MVA was 5.3±1.4cm 2 and mean gradient pre-implantation was 1.8±0.8mmHg. After the procedure, MVA reduced to 2.9±0.8cm 2 and mean gradient was 2.8±1.4mmHg. Both 3D planimetry and mean gradient were very significantly correlated (r −0.5; p<0.001) (Figure 1), whereas no correlation was note between mean gradient and PHT (r 0.17; p=0.117) Conclusion: After MitraClip implantation, the assessment of mitral valve area by 3D planimetry is significantly correlated with the transmitral mean gradient, unlike PHT. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Valvular Heart Disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0127 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25630.xml