Deep learning for automated left ventricular outflow tract diameter measurements in 2D echocardiography. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Deep learning for automated left ventricular outflow tract diameter measurements in 2D echocardiography. (14th October 2021)
- Main Title:
- Deep learning for automated left ventricular outflow tract diameter measurements in 2D echocardiography
- Authors:
- Zha, S Z
Rogstadkjernet, M
Klaeboe, L G
Skulstad, H
Edvardsen, T
Samset, E
Brekke, P H - Abstract:
- Abstract: Background: Left ventricular outflow tract diameter (LVOTd) is routinely measured to calculate stroke volume and estimate aortic valve area by the continuity equation. Despite LVOTd being regularly measured clinically, significant inter- and intraobserver variability is evident. This variability is highly impactful on both aortic stenosis evaluation and cardiac output calculation due to the squaring of the LVOT radius. Purpose: We aimed to investigate if LVOTd measurements from clinical echocardiographic examinations could be used in a deep learning (DL) model to automatically perform LVOTd measurements with equivalent accuracy and improved consistency compared to current practice. Methods: Data was collected from clinical echocardiographic examinations performed on 656 consecutive patients admitted to the cardiac catheterization laboratory at a university hospital in January – December 2018. Parasternal views with cardiologist annotated LVOTd coordinates were assessed for 1314 echocardiographic still images. The quality of the still image and annotated LVOT ground truth were individually graded as high, medium and low by experienced cardiologists to establish a rigorous training basis. Spatial geometry data was preserved for each still image in order to distinguish between different degrees of image zoom. Data was randomly split into training, validation and testing sets (68%, 17%, 15%). A fully convolutional network based on the Resnet50 architecture was usedAbstract: Background: Left ventricular outflow tract diameter (LVOTd) is routinely measured to calculate stroke volume and estimate aortic valve area by the continuity equation. Despite LVOTd being regularly measured clinically, significant inter- and intraobserver variability is evident. This variability is highly impactful on both aortic stenosis evaluation and cardiac output calculation due to the squaring of the LVOT radius. Purpose: We aimed to investigate if LVOTd measurements from clinical echocardiographic examinations could be used in a deep learning (DL) model to automatically perform LVOTd measurements with equivalent accuracy and improved consistency compared to current practice. Methods: Data was collected from clinical echocardiographic examinations performed on 656 consecutive patients admitted to the cardiac catheterization laboratory at a university hospital in January – December 2018. Parasternal views with cardiologist annotated LVOTd coordinates were assessed for 1314 echocardiographic still images. The quality of the still image and annotated LVOT ground truth were individually graded as high, medium and low by experienced cardiologists to establish a rigorous training basis. Spatial geometry data was preserved for each still image in order to distinguish between different degrees of image zoom. Data was randomly split into training, validation and testing sets (68%, 17%, 15%). A fully convolutional network based on the Resnet50 architecture was used with a custom loss function with heatmap regression. Image augmentations were added to extend the dataset. Results: When including echocardiographic images of any quality (n=1314) in the model training and inference, the median absolute difference between cardiologist LVOTd and DL LVOTd was 0.97 mm (95% Confidence interval (CI) 0.79–1.14). Using only high and medium quality still images and ground truth (n=869) in the training and inference, median absolute difference decreased to 0.81 mm (95% CI 0.60–0.96). Adding image augmentations to this dataset further improved the model, resulting in a median LVOTd absolute difference of 0.66 mm (95% CI 0.51–0.78). The LVOTd error in inference increased with decreasing image quality, as shown in Figure 1, with two predictions (0.9%) failing completely. Conclusion: Deep learning models are capable of measuring LVOTd with comparable accuracy to cardiologists when trained on clinical data. Data quality affects both training and inference. Even with a slightly lower accuracy when used on lower quality echocardiographic images, DL-assisted LVOT measurement has a clear potential to increase repeatability and consistency of LVOTd measurements. FUNDunding Acknowledgement: Type of funding sources: Public Institution(s). Main funding source(s): Research Council of Norway (Norges forskningsråd) … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Artificial Intelligence (Machine Learning, Deep Learning)
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.3056 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25626.xml