Left atrial appendage remodeling following percutaneous closure with WATCHMAN 2.5 and FLX: insights from the WATCH-DUAL registry. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Left atrial appendage remodeling following percutaneous closure with WATCHMAN 2.5 and FLX: insights from the WATCH-DUAL registry. (14th October 2021)
- Main Title:
- Left atrial appendage remodeling following percutaneous closure with WATCHMAN 2.5 and FLX: insights from the WATCH-DUAL registry
- Authors:
- Mahmoudi, K
Galea, R
Elhadad, S
Rezine, L Z
Sebag, F
Landolff, Q
Raber, L
Amabile, N - Abstract:
- Abstract: Background: Percutaneous left atrial appendage closure (LAAC) has emerged as a valid option for prevention of thromboembolic events in patients with non-valvular atrial fibrillation and contraindications for oral anticoagulation. The most recent devices have been created to improve the intervention efficiency and to allow the procedure in a wider range of anatomies. The new-generation Watchman FLX (WMFLX) features a new design but its in vivo performances have not been compared to the previous WATCHMAN 2.5 (WM2.5) prosthesis. Hence, the data regarding conformability, compression and device-related LAA remodeling are scarce. Purpose: To compare the anatomical results of WM2.5 and WMFLX implantation and impact on LAA dimensions. Methods: This study included LAAC patients from the WATCH-DUAL registry who benefited from a pre- and post-intervention CT scan. The WATCH-DUAL study was a dual center observational study including all the LAAC procedures prospectively collected in local registries from two high-volume centres between November 2017 and December 2020. The LAA and device dimensions were measured in a centralized core lab by 3D CT scan reconstruction methods, focusing on the device landing zone (LZ/defined as the cross section of the appendage that was perpendicular to its axis and connected the circumflex artery to a point 1 to 2 cm inside the LAA). Results: This analysis included n=107 patients (n=58 WMFLX, n=49 WM2.5). The patients clinical profiles didn'tAbstract: Background: Percutaneous left atrial appendage closure (LAAC) has emerged as a valid option for prevention of thromboembolic events in patients with non-valvular atrial fibrillation and contraindications for oral anticoagulation. The most recent devices have been created to improve the intervention efficiency and to allow the procedure in a wider range of anatomies. The new-generation Watchman FLX (WMFLX) features a new design but its in vivo performances have not been compared to the previous WATCHMAN 2.5 (WM2.5) prosthesis. Hence, the data regarding conformability, compression and device-related LAA remodeling are scarce. Purpose: To compare the anatomical results of WM2.5 and WMFLX implantation and impact on LAA dimensions. Methods: This study included LAAC patients from the WATCH-DUAL registry who benefited from a pre- and post-intervention CT scan. The WATCH-DUAL study was a dual center observational study including all the LAAC procedures prospectively collected in local registries from two high-volume centres between November 2017 and December 2020. The LAA and device dimensions were measured in a centralized core lab by 3D CT scan reconstruction methods, focusing on the device landing zone (LZ/defined as the cross section of the appendage that was perpendicular to its axis and connected the circumflex artery to a point 1 to 2 cm inside the LAA). Results: This analysis included n=107 patients (n=58 WMFLX, n=49 WM2.5). The patients clinical profiles didn't differ, except for a higher proportion of coronary artery disease in WM2.5 group. The LAA dimensions were comparable between groups. There was a significantly higher proportion of chickenwing shapes in the WMFLX patients. The mean device baseline diameter was in the WMFLX compared to the WM2.5 patients (28.8±0.5 vs. 25.7±0.4 mm, p<0.001). The median delay for CT control was 48 (43–62) days. The LZ area (451 (363–521) vs. 366 (260–459) mm 2, p<0.001) and minimal diameter (23.0 (20.7–24.8) vs. 18.7 (15.9–21.8) mm, p<0.001) significantly increased after implantation among patients. The LZ area increase absolute value and percentage were 101 (18–151) mm 2 and 28 (4–54) % respectively. The LZ dimensions increase was more pronounced in the WMFLX group: these patients exhibited post LAAC larger LZ area and dimensions compared to the WM2.5 cases. The LAA eccentricity was reduced after implantation: the ratio LZ maximal/LZ minimal diameter significantly decreased for all patients (r=1.28 (1.18–1.40) vs. 1.06 (1.05–1.09), p<0.001). Comparable results were observed in WMFLX and WM2.5 patients. A multivariable regression analysis demonstrated that baseline LAA length, baseline LZ eccentricity and WM FLX use were independent predictors of LAA remodeling/dimensions increase. Conclusion: LAA dimensions increased over time at the site of WM prosthesis implantation suggesting a local positive appendage remodeling after procedure. This phenomenon appears to be more pronounced with the WMFLX device. FUNDunding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Left Atrial Appendage (LAA) Closure
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.2237 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25626.xml