Utility of device-derived daily activity, a novel digital biomarker, to predict ventricular arrhythmias – data from the CERTITUDE registry. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Utility of device-derived daily activity, a novel digital biomarker, to predict ventricular arrhythmias – data from the CERTITUDE registry. (14th October 2021)
- Main Title:
- Utility of device-derived daily activity, a novel digital biomarker, to predict ventricular arrhythmias – data from the CERTITUDE registry
- Authors:
- Kutyifa, V
Rosero, S
Harrel, C
Singh, J
Hicks, J
Chinitz, L
Varma, N
Piccini, J
Turakhia, M - Abstract:
- Abstract: Background: While there have been prior studies showing an association between activity and outcomes, there have been no studies examining the temporal relationship between device-derived daily activity, a novel digital biomarker, and ventricular tachyarrhythmias (VT). Purpose: In a big dataset with over 55, 000 pacemaker, ICD, and CRT devices, we aimed to identify whether changes in activity predict VT, or else VT predict changes in activity. Methods: The CERTITUDE registry comprises a de-identified database of over 55, 000 U.S. BIOTRONIK pacemaker, ICD, CRT devices, and loop recorders active on Home Monitoring®. Daily data on leads, arrhythmias, and physiological parameters such as activity are captured. Patient activity is reported daily as percentage active during the day, assessed by a one-axis accelerometer at ∼0.4 Hz frequency. Analysis to ascertain temporal changes in device-derived activity associated with treated VT was performed using the first event per device and 7-day activity windows (baseline, pre- and post-event). Baseline period was defined as 31–38 days prior to VT. VT events were categorized by heart rate (≤200 bpm, >200 bpm) and treatment (shock with or without ATP, ATP alone). Differences in activity between baseline, and pre- and post-VT were analyzed using the binomial proportion test. Results: A total of 16, 475 devices (9732 ICDs, 6743 CRT-Ds) had activity data available for analysis. The cumulative follow-up duration was 18, 355 yearsAbstract: Background: While there have been prior studies showing an association between activity and outcomes, there have been no studies examining the temporal relationship between device-derived daily activity, a novel digital biomarker, and ventricular tachyarrhythmias (VT). Purpose: In a big dataset with over 55, 000 pacemaker, ICD, and CRT devices, we aimed to identify whether changes in activity predict VT, or else VT predict changes in activity. Methods: The CERTITUDE registry comprises a de-identified database of over 55, 000 U.S. BIOTRONIK pacemaker, ICD, CRT devices, and loop recorders active on Home Monitoring®. Daily data on leads, arrhythmias, and physiological parameters such as activity are captured. Patient activity is reported daily as percentage active during the day, assessed by a one-axis accelerometer at ∼0.4 Hz frequency. Analysis to ascertain temporal changes in device-derived activity associated with treated VT was performed using the first event per device and 7-day activity windows (baseline, pre- and post-event). Baseline period was defined as 31–38 days prior to VT. VT events were categorized by heart rate (≤200 bpm, >200 bpm) and treatment (shock with or without ATP, ATP alone). Differences in activity between baseline, and pre- and post-VT were analyzed using the binomial proportion test. Results: A total of 16, 475 devices (9732 ICDs, 6743 CRT-Ds) had activity data available for analysis. The cumulative follow-up duration was 18, 355 years (5.6 million days with transmission). Of the 2636 VT events analyzed, 1409 had a heart rate >200 bpm, and 593 were treated with shock. Patients with VT events >200 bpm treated with shock had a significant reduction in activity post-VT with a median −8.7% reduction (IQR −24.6%; 7.3%, p<0.001). However, there was no reduction in activity before the VT>200 bpm (p=0.690) (Figure). VT events >200 bpm treated with ATP alone were not associated with reduction in activity before or after the episode. Similarly, VT events ≤200 bpm treated with shock were also associated with a reduction in activity following the event (−5.8%, IQR −29.5, 12.3%, p=0.003), but not prior to the VT event. Conclusions: In this report from the CERTITUDE registry, we have shown a temporal decline in device-derived activity following ventricular arrhythmias>200 bpm and ≤200 bpm treated with a shock, but not in patients treated with ATP. Monitoring device-derived activity post-VT events with a shock could provide relevant clinical information and potentially warrant intensified treatment. FUNDunding Acknowledgement: Type of funding sources: Private company. Main funding source(s): Biotronik … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Big Data and Digital Twin
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.3073 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25626.xml