Diagnostic value of coronary flow reserve assessment by dynamic 99mTc-MIBI SPECT-CZT gamma camera for the detection of coronary artery disease. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic value of coronary flow reserve assessment by dynamic 99mTc-MIBI SPECT-CZT gamma camera for the detection of coronary artery disease. (14th October 2021)
- Main Title:
- Diagnostic value of coronary flow reserve assessment by dynamic 99mTc-MIBI SPECT-CZT gamma camera for the detection of coronary artery disease
- Authors:
- Cygulska, K M
Blaszczyk, M
Kasprzak, J D
Wejner-Mik, P
Frynas-Jonczyk, K
Plachcinska, A
Kusmierek, J
Cichocki, P
Lipiec, P - Abstract:
- Abstract: Background: Coronary flow reserve (CFR) obtained by dynamic acquisition of myocardial blood flow using 99mTc-MIBI SPECT-CZT gamma camera may be useful to diagnose myocardial perfusion defects in patients with coronary artery disease (CAD). Purpose: To assess the feasibility and diagnostic value of SPECT-derived CFR in patients with suspected of confirmed CAD. Methods: The study group comprised 55 patients (pts) (43.6% females, mean age 64.6±8.4 years) with suspected CAD who were referred for scheduled coronary angiography. All pts underwent myocardial perfusion study with solid-state CZT nuclear camera (dipyridamole stress protocol) to calculate myocardial blood flow reserve. We measured total CFR, as well as CFR in three coronary territories: left anterior descending artery (LAD CFR), right coronary artery (RCA CFR) and left circumflex artery (LCx CFR). Results: On coronary angiography 27 pts were found to have significant CAD (at least one major coronary artery ≥70% narrowed). Mean total CFR in pts with CAD was lower than in pts without CAD (1.73±0.59 vs 2.09±0.56, respectively, p=0.02). Similar differences were noted in LAD territory (1.47±0.57 vs 2.00±0.57; respectively, p=0.004) and RCA territory (1.55±0.54 vs 2.01±0.62; respectively, p=0.03). However, the differences in LCx CFR between CAD and no-CAD group did not reach statistical significance. Modest, but significant correlations were detected between LAD CFR and the percentage of LAD stenosis (r=−0.3;Abstract: Background: Coronary flow reserve (CFR) obtained by dynamic acquisition of myocardial blood flow using 99mTc-MIBI SPECT-CZT gamma camera may be useful to diagnose myocardial perfusion defects in patients with coronary artery disease (CAD). Purpose: To assess the feasibility and diagnostic value of SPECT-derived CFR in patients with suspected of confirmed CAD. Methods: The study group comprised 55 patients (pts) (43.6% females, mean age 64.6±8.4 years) with suspected CAD who were referred for scheduled coronary angiography. All pts underwent myocardial perfusion study with solid-state CZT nuclear camera (dipyridamole stress protocol) to calculate myocardial blood flow reserve. We measured total CFR, as well as CFR in three coronary territories: left anterior descending artery (LAD CFR), right coronary artery (RCA CFR) and left circumflex artery (LCx CFR). Results: On coronary angiography 27 pts were found to have significant CAD (at least one major coronary artery ≥70% narrowed). Mean total CFR in pts with CAD was lower than in pts without CAD (1.73±0.59 vs 2.09±0.56, respectively, p=0.02). Similar differences were noted in LAD territory (1.47±0.57 vs 2.00±0.57; respectively, p=0.004) and RCA territory (1.55±0.54 vs 2.01±0.62; respectively, p=0.03). However, the differences in LCx CFR between CAD and no-CAD group did not reach statistical significance. Modest, but significant correlations were detected between LAD CFR and the percentage of LAD stenosis (r=−0.3; p=0.02). Total CFR has acceptable diagnostic value for detecting significant CAD (AUC=0.672; p=0.03). The criterion with the highest diagnostic accuracy was CFR <1.8 – its sensitivity was 63%, specificity 71.4%, and overall accuracy 67%. In analysis of coronary territories the highest diagnostic value was achieved for CFR LAD (AUC=0.744; p=0.007). Conclusions: SPECT-derived CFR provides acceptable diagnostic accuracy for the detection of significant CAD. FUNDunding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Noninvasive Diagnostic Methods
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.1180 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25625.xml