Reference values for intracoronary doppler flow velocity-derived hyperaemic microvascular resistance index. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Reference values for intracoronary doppler flow velocity-derived hyperaemic microvascular resistance index. (14th October 2021)
- Main Title:
- Reference values for intracoronary doppler flow velocity-derived hyperaemic microvascular resistance index
- Authors:
- Feenstra, R G T
Seitz, A
Boerhout, C K M
De Winter, R J
Ong, P
Beijk, M A M
Piek, J J
Sechtem, U
Van De Hoef, T P - Abstract:
- Abstract: Background: Invasive assessments of microvascular function are rapidly becoming an integral part of physiological assessment in chronic coronary syndromes. Objective: We aimed to establish a reference range for Doppler flow velocity-derived hyperaemic microvascular resistance index in a cohort of ANOCA patients with no structural pathophysiological alterations in the coronary circulation. Methods: The reference population consisted of ANOCA patients undergoing invasive coronary vasomotor function assessment who had a coronary flow reserve (CFR) >2.5, and had either (1) tested negatively for spasm provocation (n=12) or (2) tested positively with only angina at rest (n=29). A reference range for HMR was established using a non-parametric method and correlations with clinical characteristics were determined using a spearman rank correlation analysis. Results: In 41 patients median HMR amounted to 1.6 mmHg/cm/s [Q1, Q3: 1.3, 2.2 mmHg/cm/s]. The reference range for HMR that is applicable to 95% of the population was 0.8 mmHg/cm/s (90% CI: 0.8–1.0 mmHg/cm/s) to 2.7 mmHg/cm/s (90% CI: 2.6–2.7 mmHg/cm/s). No significant correlations were found between HMR and clinical characteristics. Conclusion: In this reference population undergoing invasive coronary vasomotor function testing, the 90% confidence interval of the HMR upper limit of normal ranges from 2.6 to 2.7 mmHg/cm/s. A >2.5 mmHg/cm/s HMR threshold can be used to identify abnormal microvascular resistance in dailyAbstract: Background: Invasive assessments of microvascular function are rapidly becoming an integral part of physiological assessment in chronic coronary syndromes. Objective: We aimed to establish a reference range for Doppler flow velocity-derived hyperaemic microvascular resistance index in a cohort of ANOCA patients with no structural pathophysiological alterations in the coronary circulation. Methods: The reference population consisted of ANOCA patients undergoing invasive coronary vasomotor function assessment who had a coronary flow reserve (CFR) >2.5, and had either (1) tested negatively for spasm provocation (n=12) or (2) tested positively with only angina at rest (n=29). A reference range for HMR was established using a non-parametric method and correlations with clinical characteristics were determined using a spearman rank correlation analysis. Results: In 41 patients median HMR amounted to 1.6 mmHg/cm/s [Q1, Q3: 1.3, 2.2 mmHg/cm/s]. The reference range for HMR that is applicable to 95% of the population was 0.8 mmHg/cm/s (90% CI: 0.8–1.0 mmHg/cm/s) to 2.7 mmHg/cm/s (90% CI: 2.6–2.7 mmHg/cm/s). No significant correlations were found between HMR and clinical characteristics. Conclusion: In this reference population undergoing invasive coronary vasomotor function testing, the 90% confidence interval of the HMR upper limit of normal ranges from 2.6 to 2.7 mmHg/cm/s. A >2.5 mmHg/cm/s HMR threshold can be used to identify abnormal microvascular resistance in daily clinical practice. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Intracoronary Flow and Pressure Measurements
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.2094 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25614.xml