Evaluation of intrafraction couch shifts for proton treatment delivery in head‐and‐neck cancer patients: Toward optimal imaging frequency. Issue 12 (14th October 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of intrafraction couch shifts for proton treatment delivery in head‐and‐neck cancer patients: Toward optimal imaging frequency. Issue 12 (14th October 2022)
- Main Title:
- Evaluation of intrafraction couch shifts for proton treatment delivery in head‐and‐neck cancer patients: Toward optimal imaging frequency
- Authors:
- Biswal, Nrusingh C.
Rodrigues, Dario B.
Yao, Weiguang
Molitoris, Jason K.
Witek, Matthew E.
Chen, Shifeng - Abstract:
- Abstract: Purpose: Treatment planning for head‐and‐neck (H&N) cancer, in particular oropharynx, nasopharynx, and paranasal sinus cases, at our center requires noncoplanar proton beams due to the complexity of the anatomy and target location. Targeting accuracy for all beams is carefully evaluated by using image guidance before delivering proton beam therapy (PBT). In this study, we analyzed couch shifts to evaluate whether imaging is required before delivering each field with different couch angles. Methods: After the Institutional Review Board approval, a retrospective analysis was performed on data from 28 H&N patients treated with PBT. Each plan was made with two‐to‐three noncoplanar and two‐to‐three coplanar fields. Cone‐beam computed tomography and orthogonal kilovoltage (kV) images were acquired for setup and before delivering each field, respectively. The Cartesian (longitudinal, vertical, and lateral) and angular (pitch and roll) shifts for each field were recorded from the treatment summary on the first two fractions and every subsequent fifth fraction. A net magnitude of the three‐dimensional (3D) shift in Cartesian coordinates was calculated, and a 3D vector was created from the 6 degrees of freedom coordinates for transforming couch shifts in the system coordinate to the beam's‐eye view. Results: A total of 3219 Cartesian and 2146 angular shift values were recorded for 28 patients. Of the Cartesian shifts, 2069 were zero (64.3%), and 1150 (35.7%) were nonzeroAbstract: Purpose: Treatment planning for head‐and‐neck (H&N) cancer, in particular oropharynx, nasopharynx, and paranasal sinus cases, at our center requires noncoplanar proton beams due to the complexity of the anatomy and target location. Targeting accuracy for all beams is carefully evaluated by using image guidance before delivering proton beam therapy (PBT). In this study, we analyzed couch shifts to evaluate whether imaging is required before delivering each field with different couch angles. Methods: After the Institutional Review Board approval, a retrospective analysis was performed on data from 28 H&N patients treated with PBT. Each plan was made with two‐to‐three noncoplanar and two‐to‐three coplanar fields. Cone‐beam computed tomography and orthogonal kilovoltage (kV) images were acquired for setup and before delivering each field, respectively. The Cartesian (longitudinal, vertical, and lateral) and angular (pitch and roll) shifts for each field were recorded from the treatment summary on the first two fractions and every subsequent fifth fraction. A net magnitude of the three‐dimensional (3D) shift in Cartesian coordinates was calculated, and a 3D vector was created from the 6 degrees of freedom coordinates for transforming couch shifts in the system coordinate to the beam's‐eye view. Results: A total of 3219 Cartesian and 2146 angular shift values were recorded for 28 patients. Of the Cartesian shifts, 2069 were zero (64.3%), and 1150 (35.7%) were nonzero (range, −7 to 11 mm). Of the angular shifts, 1034 (48.2%) were zero, and 1112 (51.8%) were nonzero (range, −3.0° to 3.2°). For 17 patients, the couch shifts increased toward the end of the treatment course. We also found that patients with higher body mass index (BMI) presented increased net couch shifts ( p < 0.001). With BMI < 27, all overall net shift averages were <2 mm, and overall maximum net shifts were <6 mm. Conclusions: These results confirm the need for orthogonal kV imaging before delivering each field of H&N PBT at our center, where a couch rotation is involved. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 12(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 12(2022)
- Issue Display:
- Volume 23, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 12
- Issue Sort Value:
- 2022-0023-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-10-14
- Subjects:
- cone‐beam CT -- couch shift -- H&N -- image‐guided radiation therapy -- kV imaging -- proton therapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13795 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25605.xml