Towards 2D dosimetry using monolithic active pixel sensors and a copper grating. (1st December 2022)
- Record Type:
- Journal Article
- Title:
- Towards 2D dosimetry using monolithic active pixel sensors and a copper grating. (1st December 2022)
- Main Title:
- Towards 2D dosimetry using monolithic active pixel sensors and a copper grating
- Authors:
- Beck, L.
Velthuis, J.J.
De Sio, C.
Pritchard, J.L.
Li, Y.
Hugtenburg, R.P. - Abstract:
- Abstract: Higher energy and intensity X-ray radiotherapy treatments are coming into wider use, having the benefit of requiring fewer treatment fractions and fewer hospital visits per patient. However, small percentage errors in multileaf collimator positioning and dose become bigger problems with higher doses per fraction. Hence, real-time treatment verification becomes essential. Where devices downstream from the patient suffer from scattering in the patient, upstream devices can disturb the therapeutic beam. Here, a method is proposed for performing dosimetry upstream using monolithic active pixel sensors, which can be made thin enough to disturb the beam by <1%. In order to calculate the dose to the tumour, a verification device needs to make a measurement of the photon field. Some photons will Compton scatter an electron in the silicon and generate a signal. However, this signal is obscured by energy deposits from contamination electrons, originating from Compton scattering in the accelerator head and air. Often extensive build-up material is added to verification devices to reduce the electron contamination and enhance the photon signal. However, this leads to degradation of the beam intensity to the patient. Instead we propose using thin strips of 50 µm thick copper in a grating pattern and measuring the difference in the signal with and without it. The contamination electrons are relatively undisturbed by the presence of the thin copper strips and the photon signalAbstract: Higher energy and intensity X-ray radiotherapy treatments are coming into wider use, having the benefit of requiring fewer treatment fractions and fewer hospital visits per patient. However, small percentage errors in multileaf collimator positioning and dose become bigger problems with higher doses per fraction. Hence, real-time treatment verification becomes essential. Where devices downstream from the patient suffer from scattering in the patient, upstream devices can disturb the therapeutic beam. Here, a method is proposed for performing dosimetry upstream using monolithic active pixel sensors, which can be made thin enough to disturb the beam by <1%. In order to calculate the dose to the tumour, a verification device needs to make a measurement of the photon field. Some photons will Compton scatter an electron in the silicon and generate a signal. However, this signal is obscured by energy deposits from contamination electrons, originating from Compton scattering in the accelerator head and air. Often extensive build-up material is added to verification devices to reduce the electron contamination and enhance the photon signal. However, this leads to degradation of the beam intensity to the patient. Instead we propose using thin strips of 50 µm thick copper in a grating pattern and measuring the difference in the signal with and without it. The contamination electrons are relatively undisturbed by the presence of the thin copper strips and the photon signal generated via Compton scattering is enhanced under the strips. Hence the difference in the two signals mostly consists of energy deposits originating from the therapeutic photons. From this the dose to the patient can be derived. The 50 μm of copper is thin enough to keep the beam attenuation below 1%, but in itself would give a total signal response which consists of 38% contamination electrons. Using the grating technique, we show that the electron contamination can be reduced to 2.6% of the total signal. This allows the photon signal only to be extracted from the data and thus the dose to patient with a very thin upstream detector can be calculated using a Monte Carlo model to extrapolate the photon flux into the tumour. … (more)
- Is Part Of:
- Journal of instrumentation. Volume 17:Number 12(2022)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 17:Number 12(2022)
- Issue Display:
- Volume 17, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 12
- Issue Sort Value:
- 2022-0017-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12-01
- Subjects:
- Dosimetry concepts and apparatus -- Instrumentation for particle-beam therapy -- Solid state detectors -- X-ray detectors
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/17/12/C12021 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25569.xml