A gas-phase standard delivery system for direct breath analysis. (1st January 2023)
- Record Type:
- Journal Article
- Title:
- A gas-phase standard delivery system for direct breath analysis. (1st January 2023)
- Main Title:
- A gas-phase standard delivery system for direct breath analysis
- Authors:
- Streckenbach, Bettina
Sakas, Justinas
Perkins, Nathan
Kohler, Malcolm
Moeller, Alexander
Zenobi, Renato - Abstract:
- Abstract: Applications for direct breath analysis by mass spectrometry (MS) are rapidly expanding. One of the more recent mass spectrometry-based approaches is secondary electrospray ionization coupled to high-resolution mass spectrometry (SESI-HRMS). Despite increasing usage, the SESI methodology still lacks standardization procedures for quality control and absolute quantification. In this study, we designed and evaluated a custom-built standard delivery system tailored for direct breath analysis. The system enables the simultaneous introduction of multiple gas-phase standard compounds into ambient MS setups in the lower parts-per-million (ppm) to parts-per-billion (ppb) range. To best mimic exhaled breath, the gas flow can be heated (37 °C–40 °C) and humidified (up to 98% relative humidity). Inter-laboratory comparison of the system included various SESI-HRMS setups, i.e. an Orbitrap and a quadrupole time-of-flight mass spectrometer (QTOF), and using both single- as well as multi-component standards. This revealed highly stable and reproducible performances with between-run variation <19% and within-run variation <20%. Independent calibration runs demonstrated high accuracy (96%–111%) and precision (>95%) for the single-compound standard acetone, while compound-specific performances were obtained for the multi-component standard. Similarly, the sensitivity varied for different compounds within the multi-component standard across all SESI-Orbitrap and -QTOF setups,Abstract: Applications for direct breath analysis by mass spectrometry (MS) are rapidly expanding. One of the more recent mass spectrometry-based approaches is secondary electrospray ionization coupled to high-resolution mass spectrometry (SESI-HRMS). Despite increasing usage, the SESI methodology still lacks standardization procedures for quality control and absolute quantification. In this study, we designed and evaluated a custom-built standard delivery system tailored for direct breath analysis. The system enables the simultaneous introduction of multiple gas-phase standard compounds into ambient MS setups in the lower parts-per-million (ppm) to parts-per-billion (ppb) range. To best mimic exhaled breath, the gas flow can be heated (37 °C–40 °C) and humidified (up to 98% relative humidity). Inter-laboratory comparison of the system included various SESI-HRMS setups, i.e. an Orbitrap and a quadrupole time-of-flight mass spectrometer (QTOF), and using both single- as well as multi-component standards. This revealed highly stable and reproducible performances with between-run variation <19% and within-run variation <20%. Independent calibration runs demonstrated high accuracy (96%–111%) and precision (>95%) for the single-compound standard acetone, while compound-specific performances were obtained for the multi-component standard. Similarly, the sensitivity varied for different compounds within the multi-component standard across all SESI-Orbitrap and -QTOF setups, yielding limits of detections from 3.1 ppb (for p -xylene) to 0.05 ppb (for 1, 8-cineol). Routinely applying the standard system throughout several weeks, allowed us to monitor instrument stability and to identify technical outliers in exhaled breath measurements. Such routine deployment of standards would significantly improve data quality and comparability, which is especially important in longitudinal and multi-center studies. Furthermore, performance validation of the system demonstrated its suitability for reliable absolute quantification while it illustrated compound-dependent behavior for SESI. … (more)
- Is Part Of:
- Journal of breath research. Volume 17:Number 1(2023)
- Journal:
- Journal of breath research
- Issue:
- Volume 17:Number 1(2023)
- Issue Display:
- Volume 17, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2023-0017-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01-01
- Subjects:
- direct breath analysis -- standardization -- reference material -- multi-component -- SESI-HRMS
Volatile organic compounds -- Analysis -- Periodicals
Clinical chemistry -- Periodicals
Bad breath -- Periodicals
Bad breath -- Treatment -- Periodicals
Bad breath -- Diagnosis -- Periodicals
616.0756 - Journal URLs:
- http://iopscience.iop.org/1752-7163/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1752-7163/acab79 ↗
- Languages:
- English
- ISSNs:
- 1752-7155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25570.xml