Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus. (November 2015)
- Record Type:
- Journal Article
- Title:
- Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus. (November 2015)
- Main Title:
- Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus
- Authors:
- Lago, M.A.
Rupérez, M.J.
Monserrat, C.
Martínez-Martínez, F.
Martínez-Sanchis, S.
Larra, E.
Díez-Ajenjo, M.A.
Peris-Martínez, C. - Abstract:
- Abstract: Purpose: The purpose of this study was the simulation of the implantation of intrastromal corneal-ring segments for patients with keratoconus. The aim of the study was the prediction of the corneal curvature recovery after this intervention. Methods: Seven patients with keratoconus diagnosed and treated by implantation of intrastromal corneal-ring segments were enrolled in the study. The 3D geometry of the cornea of each patient was obtained from its specific topography and a hyperelastic model was assumed to characterize its mechanical behavior. To simulate the intervention, the intrastromal corneal-ring segments were modeled and placed at the same location at which they were placed in the surgery. The finite element method was then used to obtain a simulation of the deformation of the cornea after the ring segment insertion. Finally, the predicted curvature was compared with the real curvature after the intervention. Results: The simulation of the ring segment insertion was validated comparing the curvature change with the data after the surgery. Results showed a flattening of the cornea which was in consonance with the real improvement of the corneal curvature. The mean difference obtained was of 0.74 mm using properties of healthy corneas. Conclusions: For the first time, a patient-specific model of the cornea has been used to predict the outcomes of the surgery after the intrastromal corneal-ring segments implantation in real patients. Graphical abstract:Abstract: Purpose: The purpose of this study was the simulation of the implantation of intrastromal corneal-ring segments for patients with keratoconus. The aim of the study was the prediction of the corneal curvature recovery after this intervention. Methods: Seven patients with keratoconus diagnosed and treated by implantation of intrastromal corneal-ring segments were enrolled in the study. The 3D geometry of the cornea of each patient was obtained from its specific topography and a hyperelastic model was assumed to characterize its mechanical behavior. To simulate the intervention, the intrastromal corneal-ring segments were modeled and placed at the same location at which they were placed in the surgery. The finite element method was then used to obtain a simulation of the deformation of the cornea after the ring segment insertion. Finally, the predicted curvature was compared with the real curvature after the intervention. Results: The simulation of the ring segment insertion was validated comparing the curvature change with the data after the surgery. Results showed a flattening of the cornea which was in consonance with the real improvement of the corneal curvature. The mean difference obtained was of 0.74 mm using properties of healthy corneas. Conclusions: For the first time, a patient-specific model of the cornea has been used to predict the outcomes of the surgery after the intrastromal corneal-ring segments implantation in real patients. Graphical abstract: Highlights: The insertion of intrastromal corneal-ring segments was simulated. The outcome of the ICRS insertion for keratoconus cornea was estimated. The simulation was compared with real post-surgery corneas. The simulated curvature of the cornea is similar to the post-surgery curvature. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 51(2015)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 51(2015)
- Issue Display:
- Volume 51, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 51
- Issue:
- 2015
- Issue Sort Value:
- 2015-0051-2015-0000
- Page Start:
- 260
- Page End:
- 268
- Publication Date:
- 2015-11
- Subjects:
- Cornea -- Intrastromal ring segments -- Biomechanical simulation -- Keratoconus
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2015.07.023 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25586.xml