Comparing optical and electromagnetic tracking systems to facilitate compatibility in sports kinematics data. Issue 1 (1st January 2021)
- Record Type:
- Journal Article
- Title:
- Comparing optical and electromagnetic tracking systems to facilitate compatibility in sports kinematics data. Issue 1 (1st January 2021)
- Main Title:
- Comparing optical and electromagnetic tracking systems to facilitate compatibility in sports kinematics data
- Authors:
- Urbanczyk, Caryn A.
Bonfiglio, Alessandro
McGregor, Alison H.
Bull, Anthony M.J. - Abstract:
- ABSTRACT: Electromagnetic (EM) tracking has been used to quantify biomechanical parameters of the lower limb and lumbar spine during ergometer rowing to improve performance and reduce injury. Optical motion capture (OMC) is potentially better suited to measure comprehensive whole-body dynamics in rowing. This study compared accuracy and precision of EM and OMC displacements by simultaneously recording kinematics during rowing trials at low, middle, and high rates on an instrumented ergometer (n=12). Trajectories calculated from OMC and EM sensors attached to the pelvis, lumbar spine, and right leg were highly correlated, but EM tracking lagged behind ergometer and OMC tracking by approximately 6%, yielding large RMS errors. When this phase-lag was corrected by least squares minimization, agreement between systems improved. Both systems demonstrated an ability to adequately track large dynamic compound movements in the sagittal plane but struggled at times to precisely track small displacements and narrow angular ranges in medial/lateral and superior/inferior directions. An OMC based tracking methodology can obtain equivalence with a previously validated EM system, for spine and lower limb metrics. Improvements in speed and consistency of data acquisition with OMC are beneficial for dynamic motion studies. Compatibility ensures continuity by maintaining the ability to compare to prior work.
- Is Part Of:
- International biomechanics. Volume 8:Issue 1(2021)
- Journal:
- International biomechanics
- Issue:
- Volume 8:Issue 1(2021)
- Issue Display:
- Volume 8, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2021-0008-0001-0000
- Page Start:
- 75
- Page End:
- 84
- Publication Date:
- 2021-01-01
- Subjects:
- Optical motion capture -- electromagnetic motion tracking -- kinematics -- rowing
Biomechanics -- Periodicals
571.43 - Journal URLs:
- http://www.tandfonline.com/ ↗
http://www.tandfonline.com/toc/tbbe20/current ↗ - DOI:
- 10.1080/23335432.2021.2003719 ↗
- Languages:
- English
- ISSNs:
- 2333-5432
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25576.xml