Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast. Issue 5 (May 2021)
- Record Type:
- Journal Article
- Title:
- Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast. Issue 5 (May 2021)
- Main Title:
- Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast
- Authors:
- Holtackers, Robert J.
Gommers, Suzanne
Van De Heyning, Caroline M.
Mihl, Casper
Smink, Jouke
Higgins, David M.
Wildberger, Joachim E.
ter Bekke, Rachel M.A. - Abstract:
- Objectives: Free-breathing 3-dimensional (3D) late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) techniques with high isotropic resolution and dark-blood contrast may optimize the delineation of myocardial scar patterns. The extended acquisition times required for such scans, however, are paralleled by a declining contrast agent concentration. Consequently, the optimal inversion time (TI) is continuously increasing. We hypothesize that a steadily increasing (dynamic) TI can compensate for this effect and can lead to improved blood nulling to optimize the dark-blood contrast. Materials and Methods: Fifty consecutive patients with previous cardiac arrhythmias, scheduled for high-resolution 3D LGE MRI, were prospectively enrolled between October 2017 and February 2020. Free-breathing 3D dark-blood LGE MRI with high isotropic resolution (1.6 × 1.6 × 1.6 mm) was performed using a conventional fixed TI (n = 25) or a dynamic TI (n = 25). The average increase in blood nulling TI per minute was obtained from Look-Locker scans before and after the 3D acquisition in the first fixed TI group. This average increment in TI was used as input to calculate the dynamic increment of the initial blood nulling TI value as set in the second dynamic TI group. Regions of interest were drawn in the left ventricular blood pool to assess mean signal intensity as a measure for blood pool suppression. Overall image quality, observer confidence, and scar demarcation were scored on aObjectives: Free-breathing 3-dimensional (3D) late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) techniques with high isotropic resolution and dark-blood contrast may optimize the delineation of myocardial scar patterns. The extended acquisition times required for such scans, however, are paralleled by a declining contrast agent concentration. Consequently, the optimal inversion time (TI) is continuously increasing. We hypothesize that a steadily increasing (dynamic) TI can compensate for this effect and can lead to improved blood nulling to optimize the dark-blood contrast. Materials and Methods: Fifty consecutive patients with previous cardiac arrhythmias, scheduled for high-resolution 3D LGE MRI, were prospectively enrolled between October 2017 and February 2020. Free-breathing 3D dark-blood LGE MRI with high isotropic resolution (1.6 × 1.6 × 1.6 mm) was performed using a conventional fixed TI (n = 25) or a dynamic TI (n = 25). The average increase in blood nulling TI per minute was obtained from Look-Locker scans before and after the 3D acquisition in the first fixed TI group. This average increment in TI was used as input to calculate the dynamic increment of the initial blood nulling TI value as set in the second dynamic TI group. Regions of interest were drawn in the left ventricular blood pool to assess mean signal intensity as a measure for blood pool suppression. Overall image quality, observer confidence, and scar demarcation were scored on a 3-point scale. Results: Three-dimensional dark-blood LGE data sets were successfully acquired in 46/50 patients (92%). The calculated average TI increase of 2.3 ± 0.5 ms/min obtained in the first fixed TI group was incorporated in the second dynamic TI group and led to a significant decrease of 72% in the mean blood pool signal intensity compared with the fixed TI group ( P < 0.001). Overall image quality ( P = 0.02), observer confidence ( P = 0.02), and scar demarcation ( P = 0.01) significantly improved using a dynamic TI. Conclusions: A steadily increasing dynamic TI improves blood pool suppression for optimized dark-blood contrast and increases observer confidence in free-breathing 3D dark-blood LGE MRI with high isotropic resolution. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Investigative radiology. Volume 56:Issue 5(2021)
- Journal:
- Investigative radiology
- Issue:
- Volume 56:Issue 5(2021)
- Issue Display:
- Volume 56, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 5
- Issue Sort Value:
- 2021-0056-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- cardiovascular diseases -- myocardial infarction -- magnetic resonance imaging -- late gadolinium enhancement
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000747 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25591.xml