Radiological and Audiological Outcomes of the LISTENT LCI-20PI Cochlear Implant Device. Issue 4 (April 2021)
- Record Type:
- Journal Article
- Title:
- Radiological and Audiological Outcomes of the LISTENT LCI-20PI Cochlear Implant Device. Issue 4 (April 2021)
- Main Title:
- Radiological and Audiological Outcomes of the LISTENT LCI-20PI Cochlear Implant Device
- Authors:
- Tan, Haoyue
Yao, Junji
Li, Yun
Zhang, Zhihua
Chen, Ying
Huang, Meiping
Sterkers, Olivier
Jia, Huan
Wu, Hao - Abstract:
- Abstract : Objective: To study the surgical results, intracochlear position of the electrode array (EA) and auditory performance of the LISTENT LCI-20PI cochlear implant device, and daily use status at 3 years. Study Design: A retrospective study. Setting: A single-tertiary referral center. Patients: Between January and December 2016, 20 patients underwent cochlear implantation using the LISTENT LCI-20PI (lateral wall EA). Intervention: Cochlear implantation. Main Outcome Measures: Measurement of cochlear size, extent of posterior tympanotomy, and insertion depth. Scalar position of the EA evaluated by 3D reconstruction. Auditory outcomes 1 year after implantation and daily use status at 3 years. Results: EAs were completely inserted in all cases with an insertion depth of 288 ± 36.8 degrees. One year later, the average sentence recognition score (SRS) was 90 ± 21.7%. EA scalar location was analyzed in 18 patients. Thirteen EAs (72.2%) were fully inserted into the scala tympani (ST) and 5 (27.8%) had shifted from the ST to the scala vestibuli (SV). There was no statistically significant difference in cochlear size, extent of posterior tympanotomy, or insertion depth between these two groups. EAs inserted by cochleostomy had a higher chance of scalar shift than those inserted via the round window (60% vs 15.4%, p = 0.099). SRS at 1 year with full ST insertion was significantly better than in those with scalar shift (99 ± 1.3% vs 83 ± 16.5%, p = 0.002). Three years afterAbstract : Objective: To study the surgical results, intracochlear position of the electrode array (EA) and auditory performance of the LISTENT LCI-20PI cochlear implant device, and daily use status at 3 years. Study Design: A retrospective study. Setting: A single-tertiary referral center. Patients: Between January and December 2016, 20 patients underwent cochlear implantation using the LISTENT LCI-20PI (lateral wall EA). Intervention: Cochlear implantation. Main Outcome Measures: Measurement of cochlear size, extent of posterior tympanotomy, and insertion depth. Scalar position of the EA evaluated by 3D reconstruction. Auditory outcomes 1 year after implantation and daily use status at 3 years. Results: EAs were completely inserted in all cases with an insertion depth of 288 ± 36.8 degrees. One year later, the average sentence recognition score (SRS) was 90 ± 21.7%. EA scalar location was analyzed in 18 patients. Thirteen EAs (72.2%) were fully inserted into the scala tympani (ST) and 5 (27.8%) had shifted from the ST to the scala vestibuli (SV). There was no statistically significant difference in cochlear size, extent of posterior tympanotomy, or insertion depth between these two groups. EAs inserted by cochleostomy had a higher chance of scalar shift than those inserted via the round window (60% vs 15.4%, p = 0.099). SRS at 1 year with full ST insertion was significantly better than in those with scalar shift (99 ± 1.3% vs 83 ± 16.5%, p = 0.002). Three years after implantation, 92% of patients were daily users and 46% were telephone users. Conclusions: The LISTENT LCI-20PI provided accredited hearing rehabilitation with a short insertion depth. Full insertion into the ST was associated with better cochlear implantation outcomes. … (more)
- Is Part Of:
- Otology & neurotology. Volume 42:Issue 4(2021)
- Journal:
- Otology & neurotology
- Issue:
- Volume 42:Issue 4(2021)
- Issue Display:
- Volume 42, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2021-0042-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- Audiologic rehabilitation -- Cochlear implants -- Image reconstruction -- Scala tympani -- Scala vestibuli
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000002963 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25590.xml