Performance of Sexually Transmitted Disease Laboratories for Chlamydia trachomatis Detection in Guangdong, China. Issue 8 (August 2021)
- Record Type:
- Journal Article
- Title:
- Performance of Sexually Transmitted Disease Laboratories for Chlamydia trachomatis Detection in Guangdong, China. Issue 8 (August 2021)
- Main Title:
- Performance of Sexually Transmitted Disease Laboratories for Chlamydia trachomatis Detection in Guangdong, China
- Authors:
- Su, Xin
Qin, Xiaolin
Chen, Wentao
Yu, Xueyin
Liao, Yiwen
Xu, Qingqing
Xue, Yaohua
Huang, Jinmei
Zheng, Heping - Abstract:
- Abstract : Background: Chlamydia trachomatis detection plays a crucial role in early diagnosis and treatment of C. trachomatis infection. In the current study, the capability of sexually transmitted disease (STD) laboratories to detect C. trachomatis was investigated in Guangdong, China. Methods: An external quality assessment panel, including 5 positive samples with different C. trachomatis loads and 2 negative samples was distributed to 654 participating laboratories in October 2019, and the test results were analyzed by Guangdong Central STD Laboratory. The use of various C. trachomatis detection methods in Guangdong from 2015 to 2019 was also retrospectively investigated. Results: Of the 654 participating STD laboratories, 559 (85.47%) used immune chromatographic-rapid diagnostic tests (IC-RDTs) to detect C. trachomatis in 2019, and 95 (14.53%) used nucleic acid amplification tests (NAATs). The rate of NAATs use increased approximately 4-fold from 2015 to 2019. The sensitivity of IC-RDTs decreased markedly from 97.32% to 30.89% with decreasing C. trachomatis load, whereas that of NAATs was 97.62% to 100% in all positive samples. With respect to negative samples the specificity of IC-RDTs was 97.13% to 97.30% and that of NAATs was 98.95% to 100%. Laboratories using IC-RDTs were less likely to detect C. trachomatis than those using NAATs in samples with C. trachomatis loads of 20000 copies/mL or less ( P < 0.0001). Further analysis indicated no significant difference ( P >Abstract : Background: Chlamydia trachomatis detection plays a crucial role in early diagnosis and treatment of C. trachomatis infection. In the current study, the capability of sexually transmitted disease (STD) laboratories to detect C. trachomatis was investigated in Guangdong, China. Methods: An external quality assessment panel, including 5 positive samples with different C. trachomatis loads and 2 negative samples was distributed to 654 participating laboratories in October 2019, and the test results were analyzed by Guangdong Central STD Laboratory. The use of various C. trachomatis detection methods in Guangdong from 2015 to 2019 was also retrospectively investigated. Results: Of the 654 participating STD laboratories, 559 (85.47%) used immune chromatographic-rapid diagnostic tests (IC-RDTs) to detect C. trachomatis in 2019, and 95 (14.53%) used nucleic acid amplification tests (NAATs). The rate of NAATs use increased approximately 4-fold from 2015 to 2019. The sensitivity of IC-RDTs decreased markedly from 97.32% to 30.89% with decreasing C. trachomatis load, whereas that of NAATs was 97.62% to 100% in all positive samples. With respect to negative samples the specificity of IC-RDTs was 97.13% to 97.30% and that of NAATs was 98.95% to 100%. Laboratories using IC-RDTs were less likely to detect C. trachomatis than those using NAATs in samples with C. trachomatis loads of 20000 copies/mL or less ( P < 0.0001). Further analysis indicated no significant difference ( P > 0.05) in detection rate among the 4 IC-RDT assays commonly used by the participating laboratories. Conclusions: Immune chromatographic-rapid diagnostic tests are commonly used for C. trachomatis detection by many laboratories in Guangdong, but their low sensitivity may lead to missed diagnoses. Nucleic acid amplification tests exhibit high sensitivity and specificity and should be recommended for C. trachomatis detection in STD laboratories. Abstract : In external quality assessment, immune chromatographic–rapid diagnostic test sensitivity decreased markedly from 97.32% to 30.89% with decreasing Chlamydia trachomatis load. Nucleic acid amplification tests with 97.62% to 100% sensitivity are recommended for C. trachomatis detection in Guangdong. … (more)
- Is Part Of:
- Sexually transmitted diseases. Volume 48:Issue 8(2021)
- Journal:
- Sexually transmitted diseases
- Issue:
- Volume 48:Issue 8(2021)
- Issue Display:
- Volume 48, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 8
- Issue Sort Value:
- 2021-0048-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Sexually transmitted diseases -- Periodicals
Sexual health -- Periodicals
616.951005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00007435-000000000-00000 ↗
http://www.stdjournal.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OLQ.0000000000001348 ↗
- Languages:
- English
- ISSNs:
- 0148-5717
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8254.486500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25571.xml