Development of a High-Throughput Quantification Method for Pazopanib Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Clinical Application in Patients With Soft Tissue Tumors. Issue 3 (June 2021)
- Record Type:
- Journal Article
- Title:
- Development of a High-Throughput Quantification Method for Pazopanib Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Clinical Application in Patients With Soft Tissue Tumors. Issue 3 (June 2021)
- Main Title:
- Development of a High-Throughput Quantification Method for Pazopanib Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Clinical Application in Patients With Soft Tissue Tumors
- Authors:
- Shiraiwa, Ken
Suzuki, Yosuke
Tanaka, Kazuhiro
Kawano, Masanori
Iwasaki, Tatsuya
Matsumoto, Asami
Tanaka, Ryota
Tatsuta, Ryosuke
Tsumura, Hiroshi
Itoh, Hiroki - Abstract:
- Abstract : Background: Pazopanib is widely used to treat renal cell carcinomas and soft tissue tumors in Japan. Pazopanib has significant therapeutic efficacy but it is associated with frequent severe adverse effects. Therapeutic drug monitoring (TDM) may help to prevent adverse effects. A more convenient and rapid pazopanib assay is desirable for the application of TDM in clinical settings. In this study, the authors developed a high-throughput method for quantifying pazopanib in human plasma using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Methods: After a simple solid-phase extraction step using a 96-well plate, pazopanib was analyzed by UHPLC-MS/MS in the positive electrospray ionization mode. Results: The novel method fulfilled the requirements of the US Food and Drug Administration and the European Medicines Agency guidelines for assay validation, and the lower limit of quantification was 0.5 mcg/mL. The calibration curves were linear over the concentration range of 0.5–100 mcg/mL. The average recovery rate was 102.0% ± 3.9% (mean ± SD). The precision was below 5.0%, and the accuracy was within 12.0% for all quality control levels. Matrix effect varied between 90.9% and 97.1%. This assay was successfully applied to TDM of pazopanib trough concentrations in 3 patients treated with the drug for soft tissue tumors. Conclusions: The authors succeeded in developing a novel high-throughput UHPLC-MS/MS method for quantifying pazopanibAbstract : Background: Pazopanib is widely used to treat renal cell carcinomas and soft tissue tumors in Japan. Pazopanib has significant therapeutic efficacy but it is associated with frequent severe adverse effects. Therapeutic drug monitoring (TDM) may help to prevent adverse effects. A more convenient and rapid pazopanib assay is desirable for the application of TDM in clinical settings. In this study, the authors developed a high-throughput method for quantifying pazopanib in human plasma using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Methods: After a simple solid-phase extraction step using a 96-well plate, pazopanib was analyzed by UHPLC-MS/MS in the positive electrospray ionization mode. Results: The novel method fulfilled the requirements of the US Food and Drug Administration and the European Medicines Agency guidelines for assay validation, and the lower limit of quantification was 0.5 mcg/mL. The calibration curves were linear over the concentration range of 0.5–100 mcg/mL. The average recovery rate was 102.0% ± 3.9% (mean ± SD). The precision was below 5.0%, and the accuracy was within 12.0% for all quality control levels. Matrix effect varied between 90.9% and 97.1%. This assay was successfully applied to TDM of pazopanib trough concentrations in 3 patients treated with the drug for soft tissue tumors. Conclusions: The authors succeeded in developing a novel high-throughput UHPLC-MS/MS method for quantifying pazopanib in human plasma. This method can be applied to TDM of patients receiving pazopanib in clinical settings. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 43:Issue 3(2021)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 43:Issue 3(2021)
- Issue Display:
- Volume 43, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 43
- Issue:
- 3
- Issue Sort Value:
- 2021-0043-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- pazopanib -- high throughput -- ultra-high performance liquid chromatography-tandem mass spectrometry -- therapeutic drug monitoring -- soft tissue tumor
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000821 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25566.xml