Deep Learning Automates Measurement of Spinopelvic Parameters on Lateral Lumbar Radiographs. Issue 12 (15th June 2021)
- Record Type:
- Journal Article
- Title:
- Deep Learning Automates Measurement of Spinopelvic Parameters on Lateral Lumbar Radiographs. Issue 12 (15th June 2021)
- Main Title:
- Deep Learning Automates Measurement of Spinopelvic Parameters on Lateral Lumbar Radiographs
- Authors:
- Schwartz, John T.
Cho, Brian H.
Tang, Peter
Schefflein, Javin
Arvind, Varun
Kim, Jun S.
Doshi, Amish H.
Cho, Samuel K. - Abstract:
- Abstract : Study Design: Cross-sectional database study. Objective: The objective of this study was to develop an algorithm for the automated measurement of spinopelvic parameters on lateral lumbar radiographs with comparable accuracy to surgeons. Summary of Background Data: Sagittal alignment measurements are important for the evaluation of spinal disorders. Manual measurement methods are time-consuming and subject to rater-dependent error. Thus, a need exists to develop automated methods for obtaining sagittal measurements. Previous studies of automated measurement have been limited in accuracy, inapplicable to common plain films, or unable to measure pelvic parameters. Methods: Images from 816 patients receiving lateral lumbar radiographs were collected sequentially and used to develop a convolutional neural network (CNN) segmentation algorithm. A total of 653 (80%) of these radiographs were used to train and validate the CNN. This CNN was combined with a computer vision algorithm to create a pipeline for the fully automated measurement of spinopelvic parameters from lateral lumbar radiographs. The remaining 163 (20%) of radiographs were used to test this pipeline. Forty radiographs were selected from the test set and manually measured by three surgeons for comparison. Results: The CNN achieved an area under the receiver-operating curve of 0.956. Algorithm measurements of L1-S1 cobb angle, pelvic incidence, pelvic tilt, and sacral slope were not significantly differentAbstract : Study Design: Cross-sectional database study. Objective: The objective of this study was to develop an algorithm for the automated measurement of spinopelvic parameters on lateral lumbar radiographs with comparable accuracy to surgeons. Summary of Background Data: Sagittal alignment measurements are important for the evaluation of spinal disorders. Manual measurement methods are time-consuming and subject to rater-dependent error. Thus, a need exists to develop automated methods for obtaining sagittal measurements. Previous studies of automated measurement have been limited in accuracy, inapplicable to common plain films, or unable to measure pelvic parameters. Methods: Images from 816 patients receiving lateral lumbar radiographs were collected sequentially and used to develop a convolutional neural network (CNN) segmentation algorithm. A total of 653 (80%) of these radiographs were used to train and validate the CNN. This CNN was combined with a computer vision algorithm to create a pipeline for the fully automated measurement of spinopelvic parameters from lateral lumbar radiographs. The remaining 163 (20%) of radiographs were used to test this pipeline. Forty radiographs were selected from the test set and manually measured by three surgeons for comparison. Results: The CNN achieved an area under the receiver-operating curve of 0.956. Algorithm measurements of L1-S1 cobb angle, pelvic incidence, pelvic tilt, and sacral slope were not significantly different from surgeon measurement. In comparison to criterion standard measurement, the algorithm performed with a similar mean absolute difference to spine surgeons for L1-S1 Cobb angle (4.30° ± 4.14° vs. 4.99° ± 5.34°), pelvic tilt (2.14° ± 6.29° vs. 1.58° ± 5.97°), pelvic incidence (4.56° ± 5.40° vs. 3.74° ± 2.89°), and sacral slope (4.76° ± 6.93° vs. 4.75° ± 5.71°). Conclusion: This algorithm measures spinopelvic parameters on lateral lumbar radiographs with comparable accuracy to surgeons. The algorithm could be used to streamline clinical workflow or perform large scale studies of spinopelvic parameters. Level of Evidence: 3 Abstract : Sagittal alignment measurements are important for evaluation of spinal disorders, but manual measurements are time-consuming and subject to rater-dependent error. This fully automated algorithm measures spinopelvic parameters with comparable accuracy to surgeons. It could be used to streamline clinical workflow or perform large scale studies of spinopelvic parameters. … (more)
- Is Part Of:
- Spine. Volume 46:Issue 12(2021)
- Journal:
- Spine
- Issue:
- Volume 46:Issue 12(2021)
- Issue Display:
- Volume 46, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2021-0046-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-15
- Subjects:
- artificial intelligence -- Automation -- interrater reliability -- machine learning -- pelvic incidence -- pelvic tilt -- radiography -- sacral slope -- sagittal alignment -- spinopelvic measurement
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000003830 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25590.xml