Performance of a True Point-of-Care Assay for HIV-1/2 Viral Load Measurement at Antenatal and Postpartum Services. (1st May 2021)
- Record Type:
- Journal Article
- Title:
- Performance of a True Point-of-Care Assay for HIV-1/2 Viral Load Measurement at Antenatal and Postpartum Services. (1st May 2021)
- Main Title:
- Performance of a True Point-of-Care Assay for HIV-1/2 Viral Load Measurement at Antenatal and Postpartum Services
- Authors:
- Meggi, Bindiya
Bollinger, Timothy
Zitha, Alcina
Mudenyanga, Chishamiso
Vubil, Adolfo
Mutsaka, Dadirayi
Nhachigule, Carina
Mabunda, Nedio
Loquiha, Osvaldo
Kroidl, Arne
Jani, Ilesh V. - Abstract:
- Abstract : Background: Timely viral load (VL) results during pregnancy and the postpartum period are crucial for HIV disease management and for preventing mother-to-child transmission. Point-of-care (POC) VL testing could reduce turnaround times and streamline patient management. We evaluated the diagnostic performance of the novel m-PIMA HIV-1/2 VL assay (Abbott, Chicago, IL) in Mozambique. Setting: The study was conducted in prenatal and postpartum consultation rooms in 2 primary health care clinics. Sample collection and testing on m-PIMA were performed by trained nurses. Methods: HIV-infected pregnant and postpartum women on antiretroviral treatment (ART) or ART naive were tested using both on-site m-PIMA POC and referral laboratory-based real-time VL assays. Linear regression analysis and Bland–Altman plots were used to calculate the agreement between both. Findings: Correlation between venous blood plasma POC and plasma laboratory-based VL was strong (r 2 = 0.850, P < 0.01), with good agreement between the methods [overall bias 0.202 log copies/mL (95% CI: 0.366 to 0.772 log copies/mL)]. Using the threshold of 1000 copies/mL, which is used to determine ART failure, the sensitivity and specificity of the POC VL assay were 95.0% (95% CI: 91.6% to 97.3%) and 96.5% (95% CI: 94.2% to 98.0%), respectively. The correlation coefficient between the venous and capillary sample types was 0.983 (r 2 = 0.966). Conclusions: On-site, nurse-performed POC VL testing is feasible andAbstract : Background: Timely viral load (VL) results during pregnancy and the postpartum period are crucial for HIV disease management and for preventing mother-to-child transmission. Point-of-care (POC) VL testing could reduce turnaround times and streamline patient management. We evaluated the diagnostic performance of the novel m-PIMA HIV-1/2 VL assay (Abbott, Chicago, IL) in Mozambique. Setting: The study was conducted in prenatal and postpartum consultation rooms in 2 primary health care clinics. Sample collection and testing on m-PIMA were performed by trained nurses. Methods: HIV-infected pregnant and postpartum women on antiretroviral treatment (ART) or ART naive were tested using both on-site m-PIMA POC and referral laboratory-based real-time VL assays. Linear regression analysis and Bland–Altman plots were used to calculate the agreement between both. Findings: Correlation between venous blood plasma POC and plasma laboratory-based VL was strong (r 2 = 0.850, P < 0.01), with good agreement between the methods [overall bias 0.202 log copies/mL (95% CI: 0.366 to 0.772 log copies/mL)]. Using the threshold of 1000 copies/mL, which is used to determine ART failure, the sensitivity and specificity of the POC VL assay were 95.0% (95% CI: 91.6% to 97.3%) and 96.5% (95% CI: 94.2% to 98.0%), respectively. The correlation coefficient between the venous and capillary sample types was 0.983 (r 2 = 0.966). Conclusions: On-site, nurse-performed POC VL testing is feasible and accurate in resource-limited primary health care settings. The operational challenge of plasma separation within clinics for POC testing was successfully overcome using minicentrifuges. The use of capillary blood could simplify the execution of the assay in a clinical environment. … (more)
- Is Part Of:
- Journal of acquired immune deficiency syndromes. Volume 87:Number 1(2021)
- Journal:
- Journal of acquired immune deficiency syndromes
- Issue:
- Volume 87:Number 1(2021)
- Issue Display:
- Volume 87, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 87
- Issue:
- 1
- Issue Sort Value:
- 2021-0087-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-01
- Subjects:
- point-of-care testing -- HIV -- viral load
AIDS (Disease) -- Periodicals
Acquired Immunodeficiency Syndrome -- Periodicals
AIDS (Disease)
Periodicals
616.9792005 - Journal URLs:
- http://journals.lww.com/jaids/pages/default.aspx ↗
http://www.jaids.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/QAI.0000000000002621 ↗
- Languages:
- English
- ISSNs:
- 1525-4135
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4644.422000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25536.xml