Cost-effective fetal lung volumetry for assessment of congenital diaphragmatic hernia. (May 2021)
- Record Type:
- Journal Article
- Title:
- Cost-effective fetal lung volumetry for assessment of congenital diaphragmatic hernia. (May 2021)
- Main Title:
- Cost-effective fetal lung volumetry for assessment of congenital diaphragmatic hernia
- Authors:
- Corroenne, Romain
Zhu, Katherine H.
Johnson, Rebecca
Mehollin-Ray, Amy R.
Shamshirsaz, Alireza A.
Nassr, Ahmed A.
Belfort, Michael A.
Cortes, Magdalena Sanz
Shetty, Anil
Lee, Wesley
Espinoza, Jimmy - Abstract:
- Abstract: Objectives: (1) To investigate the reproducibility of total fetal lung volume (TFLV) measurements using a free 3D modeling software (3DSlicer); (2) To correlate these measurements with lung-to-head ratio (LHR) or TFLV measured using PACS and; (3) To determine the role of 3DSlicer in predicting perinatal outcomes in cases with congenital diaphragmatic hernia (CDH) who had fetal tracheal occlusion (FETO). Methods: Retrospective cohort study between 2012 and 2017 at Texas Children's Hospital (2011–2017), including all patients who underwent FETO for CDH. LHR was measured by ultrasound and TFLV was measured by MRI at the time of referral and 6 weeks after FETO using 3DSlicer and PACS. We evaluated intra- and inter-rater reliability of TFLV measurement using 3DSlicer, infant survival to 1 year, need for ECMO and pulmonary hypertension. Results: The intra- and inter-rater reliability of TFLV measured with 3DSlicer was excellent before and after FETO (Intra-class correlation coefficient: 0.98−0.99 and 0.94−0.99, respectively). There was a good correlation between TFLV measured with PACS and with 3DSlicer before and after FETO (r = 0.78 and r = 0.99, respectively). Similarly, there was a good correlation between TFLV measurements using PACS or 3DSlicer and LHR after FETO (r = 0.86 and r = 0.88, respectively). Infants who survived to 1 year had a significantly higher TFLV evaluated with 3DSlicer before FETO compared to non-surviving infants (OR = 1.16[1.1–1.3], p = 0.03) asAbstract: Objectives: (1) To investigate the reproducibility of total fetal lung volume (TFLV) measurements using a free 3D modeling software (3DSlicer); (2) To correlate these measurements with lung-to-head ratio (LHR) or TFLV measured using PACS and; (3) To determine the role of 3DSlicer in predicting perinatal outcomes in cases with congenital diaphragmatic hernia (CDH) who had fetal tracheal occlusion (FETO). Methods: Retrospective cohort study between 2012 and 2017 at Texas Children's Hospital (2011–2017), including all patients who underwent FETO for CDH. LHR was measured by ultrasound and TFLV was measured by MRI at the time of referral and 6 weeks after FETO using 3DSlicer and PACS. We evaluated intra- and inter-rater reliability of TFLV measurement using 3DSlicer, infant survival to 1 year, need for ECMO and pulmonary hypertension. Results: The intra- and inter-rater reliability of TFLV measured with 3DSlicer was excellent before and after FETO (Intra-class correlation coefficient: 0.98−0.99 and 0.94−0.99, respectively). There was a good correlation between TFLV measured with PACS and with 3DSlicer before and after FETO (r = 0.78 and r = 0.99, respectively). Similarly, there was a good correlation between TFLV measurements using PACS or 3DSlicer and LHR after FETO (r = 0.86 and r = 0.88, respectively). Infants who survived to 1 year had a significantly higher TFLV evaluated with 3DSlicer before FETO compared to non-surviving infants (OR = 1.16[1.1–1.3], p = 0.03) as well as a significantly higher TFLV evaluated by 3DSlicer after FETO (OR = 1.2[1–1.4], p = 0.04). Conclusion: Lung volume measurements using free 3DSlicer in infants with severe CDH who underwent FETO are reproducible and reliable, and have comparable predictive capability for survival as those measured using conventional software. … (more)
- Is Part Of:
- European journal of obstetrics, gynecology, and reproductive biology. Volume 260(2021)
- Journal:
- European journal of obstetrics, gynecology, and reproductive biology
- Issue:
- Volume 260(2021)
- Issue Display:
- Volume 260, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 260
- Issue:
- 2021
- Issue Sort Value:
- 2021-0260-2021-0000
- Page Start:
- 22
- Page End:
- 28
- Publication Date:
- 2021-05
- Subjects:
- Congenital diaphragmatic hernia -- Fetal tracheal occlusion -- Fetal surgery -- 3DSlicer
Obstetrics -- Periodicals
Gynecology -- Periodicals
Reproductive health -- Periodicals
Gynecology -- Periodicals
Obstetrics -- Periodicals
Reproduction -- Periodicals
Obstétrique -- Périodiques
Gynécologie -- Périodiques
Reproduction -- Périodiques
Verloskunde
Gynaecologie
Voortplanting (biologie)
Gynecology
Obstetrics
Reproduction
Electronic journals
Periodicals
Electronic journals
618.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03012115 ↗
http://www.ingentaconnect.com/content/els/00282243 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03012115 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03012115 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejogrb.2021.02.025 ↗
- Languages:
- English
- ISSNs:
- 0301-2115
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.733000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25565.xml