Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position. Issue 2 (3rd February 2023)
- Record Type:
- Journal Article
- Title:
- Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position. Issue 2 (3rd February 2023)
- Main Title:
- Improving Technical Outcome in Osteochondral Allograft Transplantation of the Femoral Trochlea: The Role of Contoured Guides, Experience Level, Graft Size, and Graft Position
- Authors:
- Delman, Connor M.
Haffner, Max
Rinaldi, Peter
Lum, Zach C.
Jamali, Amir A.
Wilson, Machelle
Lee, Cassandra A. - Abstract:
- Background: The use of coring instrumentation for osteochondral allograft (OCA) transplantation of the femoral trochlea is challenging due to the complex topography of this anatomical area. Purpose: We sought to determine the effect of flat guides versus guides contoured to the surface of the trochlea on graft step-off in trochlear OCAs performed on a foam bone model. We also determined the effect of surgeon experience level and graft size on step-off. Study Design: Controlled laboratory study. Methods: Allograft harvesters were produced in 3 different sequential sizes with either a flat or a contoured undersurface. The guides matched one another in all aspects of shape and size except for the undersurface contour. The contoured undersurface generally matched the surface of the bone model trochlea but was not customized to that surface. A total of 72 foam femora were obtained. Identical trochlear stellate lesions of 3 different sizes (small, medium, and large) were created using 3-dimensional printed surface templates. A total of 6 surgeons (3 attending and 3 resident surgeons) performed OCAs of each trochlear lesion. Each surgeon performed 1 graft for each size and each guide type (n = 6 per surgeon). A specialized digital caliper was prepared that allowed the measurement of graft step-off to within 0.01 mm at a distance of 5 mm between the 2 sensors. The measurements were performed at 8 positions around the clockface of the grafts. Results: Grafts performed with theBackground: The use of coring instrumentation for osteochondral allograft (OCA) transplantation of the femoral trochlea is challenging due to the complex topography of this anatomical area. Purpose: We sought to determine the effect of flat guides versus guides contoured to the surface of the trochlea on graft step-off in trochlear OCAs performed on a foam bone model. We also determined the effect of surgeon experience level and graft size on step-off. Study Design: Controlled laboratory study. Methods: Allograft harvesters were produced in 3 different sequential sizes with either a flat or a contoured undersurface. The guides matched one another in all aspects of shape and size except for the undersurface contour. The contoured undersurface generally matched the surface of the bone model trochlea but was not customized to that surface. A total of 72 foam femora were obtained. Identical trochlear stellate lesions of 3 different sizes (small, medium, and large) were created using 3-dimensional printed surface templates. A total of 6 surgeons (3 attending and 3 resident surgeons) performed OCAs of each trochlear lesion. Each surgeon performed 1 graft for each size and each guide type (n = 6 per surgeon). A specialized digital caliper was prepared that allowed the measurement of graft step-off to within 0.01 mm at a distance of 5 mm between the 2 sensors. The measurements were performed at 8 positions around the clockface of the grafts. Results: Grafts performed with the contoured guides had a mean step-off of 0.43 ± 0.37 mm. Grafts performed with the flat guides had a mean step-off of 0.74 ± 0.78 mm ( P < .0001). Experience level did not have a significant effect on graft step-off ( P = .81). There was no identifiable pattern indicating higher step-off at any one position on the clockface. Conclusion: In this study, contoured grafts had significantly lower step-offs compared with flat guides. Experience level, clockface position, and graft size did not affect step-off. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 11:Issue 2(2023)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 11:Issue 2(2023)
- Issue Display:
- Volume 11, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2023-0011-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-02-03
- Subjects:
- patellofemoral -- trochlea -- cartilage -- osteochondral allograft -- knee
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/23259671221145208 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25544.xml