Comparison of hemodynamics in biological surgical aortic valve replacement and transcatheter aortic valve implantation: An in‐silico study. Issue 2 (27th September 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of hemodynamics in biological surgical aortic valve replacement and transcatheter aortic valve implantation: An in‐silico study. Issue 2 (27th September 2022)
- Main Title:
- Comparison of hemodynamics in biological surgical aortic valve replacement and transcatheter aortic valve implantation: An in‐silico study
- Authors:
- Franke, Benedikt
Schlief, Adriano
Walczak, Lars
Sündermann, Simon
Unbehaun, Axel
Kempfert, Jörg
Solowjowa, Natalia
Kühne, Titus
Goubergrits, Leonid - Abstract:
- Abstract: Objectives: In aortic valve replacement (AVR), the treatment strategy as well as the model and size of the implanted prosthesis have a major impact on the postoperative hemodynamics and thus on the clinical outcome. Preinterventional prediction of the hemodynamics could support the treatment decision. Therefore, we performed paired virtual treatment with transcatheter AVR (TAVI) and biological surgical AVR (SAVR) and compared hemodynamic outcomes using numerical simulations. Methods: 10 patients with severe aortic stenosis (AS) undergoing TAVI were virtually treated with both biological SAVR and TAVI to compare post‐interventional hemodynamics using numerical simulations of peak‐systolic flow. Virtual treatment procedure was done using an in‐house developed tool based on position‐based dynamics methodology, which was applied to the patient's anatomy including LVOT, aortic root and aorta. Geometries were automatically segmented from dynamic CT‐scans and patient‐specific flow rates were calculated by volumetric analysis of the left ventricle. Hemodynamics were assessed using the STAR CCM+ software by solving the RANS equations. Results: Virtual treatment with TAVI resulted in realistic hemodynamics comparable to echocardiographic measurements (median difference in transvalvular pressure gradient [TPG]: −0.33 mm Hg). Virtual TAVI and SAVR showed similar hemodynamic functions with a mean TPG with standard deviation of 8.45 ± 4.60 mm Hg in TAVI and 6.66 ± 3.79 mm Hg inAbstract: Objectives: In aortic valve replacement (AVR), the treatment strategy as well as the model and size of the implanted prosthesis have a major impact on the postoperative hemodynamics and thus on the clinical outcome. Preinterventional prediction of the hemodynamics could support the treatment decision. Therefore, we performed paired virtual treatment with transcatheter AVR (TAVI) and biological surgical AVR (SAVR) and compared hemodynamic outcomes using numerical simulations. Methods: 10 patients with severe aortic stenosis (AS) undergoing TAVI were virtually treated with both biological SAVR and TAVI to compare post‐interventional hemodynamics using numerical simulations of peak‐systolic flow. Virtual treatment procedure was done using an in‐house developed tool based on position‐based dynamics methodology, which was applied to the patient's anatomy including LVOT, aortic root and aorta. Geometries were automatically segmented from dynamic CT‐scans and patient‐specific flow rates were calculated by volumetric analysis of the left ventricle. Hemodynamics were assessed using the STAR CCM+ software by solving the RANS equations. Results: Virtual treatment with TAVI resulted in realistic hemodynamics comparable to echocardiographic measurements (median difference in transvalvular pressure gradient [TPG]: −0.33 mm Hg). Virtual TAVI and SAVR showed similar hemodynamic functions with a mean TPG with standard deviation of 8.45 ± 4.60 mm Hg in TAVI and 6.66 ± 3.79 mm Hg in SAVR ( p = 0.03) while max. Wall shear stress being 12.6 ± 4.59 vs. 10.2 ± 4.42 Pa ( p = 0.001). Conclusions: Using the presented method for virtual treatment of AS, we were able to reliably predict post‐interventional hemodynamics. TAVI and SAVR show similar hemodynamics in a pairwise comparison. Abstract : We performed virtual treatment with TAVI and biological SAVR in 10 patients with aortic stenosis and compared post‐interventional hemodynamics using computational fluid dynamics. Both treatments resulted in good outcomes with comparable figures for TPG and WSS, with SAVR performing slightly better. Our study was motivated by the recent adjustment of the ECS/EACTS guidelines for treatment of aortic stenosis, which no longer advise against TAVI procedure for intermediate‐risk patients, indicating that TAVI and SAVR populations will increasingly overlap in the future. … (more)
- Is Part Of:
- Artificial organs. Volume 47:Issue 2(2023)
- Journal:
- Artificial organs
- Issue:
- Volume 47:Issue 2(2023)
- Issue Display:
- Volume 47, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 47
- Issue:
- 2
- Issue Sort Value:
- 2023-0047-0002-0000
- Page Start:
- 352
- Page End:
- 360
- Publication Date:
- 2022-09-27
- Subjects:
- hemodynamics -- surgical aortic valve replacement -- TAVI -- virtual treatment
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.14405 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25535.xml