No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial. Issue 2 (March 2023)
- Record Type:
- Journal Article
- Title:
- No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial. Issue 2 (March 2023)
- Main Title:
- No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial
- Authors:
- Bunyoz, Kristine I
Tsikandylakis, Georgios
Mortensen, Kristian
Gromov, Kirill
Mohaddes, Maziar
Malchau, Henrik
Troelsen, Anders - Abstract:
- Aim: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. Methods: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36–44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. Results: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08–0.15) versus 0.12 µg/L (0.08–0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50–0.59) versus 0.50 µg/L (0.50–1.20), p = 0.059, for chromium and 1.58 µg/L (1.38–2.05) versus 1.48 µg/L (1.14–1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12–0.24) versus 0.18 µg/L (0.12–0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50–0.50) versus 0.50 µg/L (0.50–0.57), p = 0.554, for chromium and 1.54 µg/L (1.16–1.87) versus 1.42 µg/L (1.01–1.72), p = 0.207 for titanium. Conclusions: The use of the largest possible metal head (36–44 mm) compared to a 32-mm head in metal–on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probablyAim: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. Methods: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36–44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. Results: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08–0.15) versus 0.12 µg/L (0.08–0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50–0.59) versus 0.50 µg/L (0.50–1.20), p = 0.059, for chromium and 1.58 µg/L (1.38–2.05) versus 1.48 µg/L (1.14–1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12–0.24) versus 0.18 µg/L (0.12–0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50–0.50) versus 0.50 µg/L (0.50–0.57), p = 0.554, for chromium and 1.54 µg/L (1.16–1.87) versus 1.42 µg/L (1.01–1.72), p = 0.207 for titanium. Conclusions: The use of the largest possible metal head (36–44 mm) compared to a 32-mm head in metal–on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels. Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704) … (more)
- Is Part Of:
- Hip international. Volume 33:Issue 2(2023)
- Journal:
- Hip international
- Issue:
- Volume 33:Issue 2(2023)
- Issue Display:
- Volume 33, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2023-0033-0002-0000
- Page Start:
- 184
- Page End:
- 192
- Publication Date:
- 2023-03
- Subjects:
- Adverse local tissue reaction -- blood metal ions -- chromium -- cobalt -- THA -- large femoral heads -- MoP -- taper corrosion -- titanium
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.1177/11207000211022623 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25525.xml