Mechanical Device Malfunction of the HeartMate II Versus the HeartMate 3 Left Ventricular Assist Device: The Rotterdam Experience. Issue 2 (13th December 2022)
- Record Type:
- Journal Article
- Title:
- Mechanical Device Malfunction of the HeartMate II Versus the HeartMate 3 Left Ventricular Assist Device: The Rotterdam Experience. Issue 2 (13th December 2022)
- Main Title:
- Mechanical Device Malfunction of the HeartMate II Versus the HeartMate 3 Left Ventricular Assist Device: The Rotterdam Experience
- Authors:
- van der Heiden, Cornelis W.
Zijderhand, Casper F.
Veen, Kevin M.
Constantinescu, Alina A.
Manintveld, Olivier C.
Brugts, Jasper J.
Bekkers, Jos A.
Birim, Ozcan
Bogers, Ad J. J. C.
Caliskan, Kadir - Abstract:
- Abstract : Mechanical device malfunction remains a known issue in left ventricular assist devices (LVADs). We investigated the incidence of mechanical device malfunction in the HeartMate II and HeartMate 3 LVADs. We conducted a retrospective study of all HeartMate II and HeartMate 3 LVADs implanted in our center. We evaluated major malfunction, potential major malfunction, minor malfunction, and need of device exchange. In total, 163 patients received an LVAD; in 63 (39%) a HeartMate II, and in 100 (61%) a HeartMate 3, median support time of respectively 24.6 months (interquartile range [IQR]: 32.4) and 21.1 months [IQR: 27.2]. Mechanical device malfunction, consisting of both major and potential major malfunction, occurred significantly less in the HeartMate 3 patients with a hazard ratio (HR) of 0.37 (95% confidence interval [CI]: 0.15–0.87, p = 0.022). Major malfunction alone occurred significantly less in HeartMate 3 patients with a HR of 0.18 (95% CI: 0.05–0.66, p = 0.009). HeartMate 3 patients had a significantly decreased hazard of a pump or outflow graft exchange (HR 0.13, 95% CI: 0.08–0.81, p = 0.008). System controller defects occurred significantly less in HM 3 patients ( p = 0.007), but battery-clips defects occurred significantly more in HM 3 patients ( p = 0.039). Major device malfunction including pump or outflow graft exchange occurred significantly less in HeartMate 3 compared to HeartMate II, while minor malfunctions were similar. Periodical assessment ofAbstract : Mechanical device malfunction remains a known issue in left ventricular assist devices (LVADs). We investigated the incidence of mechanical device malfunction in the HeartMate II and HeartMate 3 LVADs. We conducted a retrospective study of all HeartMate II and HeartMate 3 LVADs implanted in our center. We evaluated major malfunction, potential major malfunction, minor malfunction, and need of device exchange. In total, 163 patients received an LVAD; in 63 (39%) a HeartMate II, and in 100 (61%) a HeartMate 3, median support time of respectively 24.6 months (interquartile range [IQR]: 32.4) and 21.1 months [IQR: 27.2]. Mechanical device malfunction, consisting of both major and potential major malfunction, occurred significantly less in the HeartMate 3 patients with a hazard ratio (HR) of 0.37 (95% confidence interval [CI]: 0.15–0.87, p = 0.022). Major malfunction alone occurred significantly less in HeartMate 3 patients with a HR of 0.18 (95% CI: 0.05–0.66, p = 0.009). HeartMate 3 patients had a significantly decreased hazard of a pump or outflow graft exchange (HR 0.13, 95% CI: 0.08–0.81, p = 0.008). System controller defects occurred significantly less in HM 3 patients ( p = 0.007), but battery-clips defects occurred significantly more in HM 3 patients ( p = 0.039). Major device malfunction including pump or outflow graft exchange occurred significantly less in HeartMate 3 compared to HeartMate II, while minor malfunctions were similar. Periodical assessment of the technical integrity of the device remains necessary during long-term LVAD support. … (more)
- Is Part Of:
- ASAIO journal. Volume 69:Issue 2(2023)
- Journal:
- ASAIO journal
- Issue:
- Volume 69:Issue 2(2023)
- Issue Display:
- Volume 69, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 69
- Issue:
- 2
- Issue Sort Value:
- 2023-0069-0002-0000
- Page Start:
- e80
- Page End:
- e85
- Publication Date:
- 2022-12-13
- Subjects:
- left ventricular assist device -- HeartMate II -- HeartMate 3 -- mechanical device malfunction
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000001877 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25500.xml