High rate pacing guided by short-term variability of repolarization prevents imminent ventricular arrhythmias autonomically by an ICD. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- High rate pacing guided by short-term variability of repolarization prevents imminent ventricular arrhythmias autonomically by an ICD. (25th November 2020)
- Main Title:
- High rate pacing guided by short-term variability of repolarization prevents imminent ventricular arrhythmias autonomically by an ICD
- Authors:
- Smoczynska, A
Loen, V
Hernandez, A.A
Beekman, H.D.M
Meine, M
Vos, M.A - Abstract:
- Abstract: Background: The anesthetized, chronic complete atrioventricular block (CAVB) dog model allows reproducible inducibility of Torsade de Pointes (TdP) arrhythmias due to ventricular remodeling and after a challenge with an IKr-blocker. High rate pacing (HRP) prevents ventricular arrhythmias, but has long-term detrimental effects on cardiac function when applied continuously. Temporal dispersion of repolarization, quantified as short-term variability (STV), increases prior to ventricular arrhythmias and has been proposed as a marker to guide HRP. Purpose: A proof-of-principle study to show STV determined automatically and in real-time by an ICD can guide HRP to prevent imminent ventricular arrhythmias. Methods: Eight CAVB dogs were implanted with an ICD (Medtronic, lead in the right ventricular (RV) apex), with software to automatically determine STV online (STV-ICD). STV was determined from the activation recovery interval (ARI) of 31 consecutive beats with the formula: STV = Σ|ARI(n+1) − ARI(n)|/(N*√2). The CAVB dogs were challenged twice with dofetilide (0.025 mg/kg i.v. in 5 minutes or until the first TdP). In the first experiment, the individual STV-ICD threshold was determined prior to the first arrhythmic event and programmed into the ICD. In a serial experiment, HRP was initiated automatically once the STV-ICD threshold was reached, by gradually increasing the heart rate to 100 bpm. Occurrence of TdPs was monitored for 10 minutes from the start of dofetilideAbstract: Background: The anesthetized, chronic complete atrioventricular block (CAVB) dog model allows reproducible inducibility of Torsade de Pointes (TdP) arrhythmias due to ventricular remodeling and after a challenge with an IKr-blocker. High rate pacing (HRP) prevents ventricular arrhythmias, but has long-term detrimental effects on cardiac function when applied continuously. Temporal dispersion of repolarization, quantified as short-term variability (STV), increases prior to ventricular arrhythmias and has been proposed as a marker to guide HRP. Purpose: A proof-of-principle study to show STV determined automatically and in real-time by an ICD can guide HRP to prevent imminent ventricular arrhythmias. Methods: Eight CAVB dogs were implanted with an ICD (Medtronic, lead in the right ventricular (RV) apex), with software to automatically determine STV online (STV-ICD). STV was determined from the activation recovery interval (ARI) of 31 consecutive beats with the formula: STV = Σ|ARI(n+1) − ARI(n)|/(N*√2). The CAVB dogs were challenged twice with dofetilide (0.025 mg/kg i.v. in 5 minutes or until the first TdP). In the first experiment, the individual STV-ICD threshold was determined prior to the first arrhythmic event and programmed into the ICD. In a serial experiment, HRP was initiated automatically once the STV-ICD threshold was reached, by gradually increasing the heart rate to 100 bpm. Occurrence of TdPs was monitored for 10 minutes from the start of dofetilide infusion in both experiments. During HRP, STV was measured offline from RV electrograms (EGM) and left ventricular (LV) monophasic action potential durations (MAPD) (STV-offline). Results: During the inducibility experiment, 8/8 dogs had repetitive TdPs and STV-ICD increased from 0.96±0.42 to 2.10±1.26 ms* (*p<0.05). During the prevention experiment, all dogs reached the STV threshold. HRP decreased STV-offline from 2.02±1.12 to 0.78±0.28 ms*, which was accompanied by prevention of TdPs in 7/8 dogs* (Figure 1). Conclusion: Temporal dispersion of repolarization, quantified as STV, can guide HRP automatically by an ICD to prevent ventricular arrhythmias. Funding Acknowledgement: Type of funding source: Public grant(s) – National budget only. Main funding source(s): Dutch Heart Foundation Public Private Partnership … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Implantable Cardioverter / Defibrillator
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0786 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25490.xml