Acute changes in mitral valve geometry after MitraClip procedure assessed by 3D transoesophageal echocardiography. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Acute changes in mitral valve geometry after MitraClip procedure assessed by 3D transoesophageal echocardiography. (25th November 2020)
- Main Title:
- Acute changes in mitral valve geometry after MitraClip procedure assessed by 3D transoesophageal echocardiography
- Authors:
- Saffioti, S
Travaglio, N
Corciu, A.I
Gorla, R
Lopopolo Rubio, A
Testa, L
De Marco, F
Tusa, M
Bedogni, F - Abstract:
- Abstract: Background: MitraClip procedure is a treatment option in patients with symptomatic mitral regurgitation (MR) and prohibitive surgical risk. Echocardiographic evaluation of mitral valve (MV) is of paramount importance for the correct identification of patient eligibility and procedural success. Our aim is to assess the acute effect of device implantation on mitral annular geometric parameters still little explored with the use of three-dimensional (3D) transoesophageal echocardiography (TEE) and to investigate its relationship with residual MR at discharge. Methods: 67 consecutive patients (mean age78.7±7.2 yrs, 41 males) undergoing percutaneous MV repair with MitraClip in our Centre were enrolled. Patients eligibility was evaluated according to the EVEREST criteria and current guidelines. Four groups were identified on the base of MR aetiology: 22 were degenerative (DMR), 19 ischemic functional (IFMR), 19 non-ischemic functional (NIFMR) and 7 atrial functional (AFMR). 3D TEE was performed before and immediately after clip deployment with MV anatomical quantification by PHILIPS® QLAB MVQ and GE® 4D-AUTO-MVQ software. Results: Severe MR (4+) was found in 17 pts, and moderate-severe MR (3+) in 50 pts. Thirteen cases were unsuccessful because of unchanged or residual MR>2+. Immediately after device positioning, almost all the evaluated parameters showed a significant modification within each group with a reduction of anterior-posterior (AP-D) and bi-commissural (CC-D)Abstract: Background: MitraClip procedure is a treatment option in patients with symptomatic mitral regurgitation (MR) and prohibitive surgical risk. Echocardiographic evaluation of mitral valve (MV) is of paramount importance for the correct identification of patient eligibility and procedural success. Our aim is to assess the acute effect of device implantation on mitral annular geometric parameters still little explored with the use of three-dimensional (3D) transoesophageal echocardiography (TEE) and to investigate its relationship with residual MR at discharge. Methods: 67 consecutive patients (mean age78.7±7.2 yrs, 41 males) undergoing percutaneous MV repair with MitraClip in our Centre were enrolled. Patients eligibility was evaluated according to the EVEREST criteria and current guidelines. Four groups were identified on the base of MR aetiology: 22 were degenerative (DMR), 19 ischemic functional (IFMR), 19 non-ischemic functional (NIFMR) and 7 atrial functional (AFMR). 3D TEE was performed before and immediately after clip deployment with MV anatomical quantification by PHILIPS® QLAB MVQ and GE® 4D-AUTO-MVQ software. Results: Severe MR (4+) was found in 17 pts, and moderate-severe MR (3+) in 50 pts. Thirteen cases were unsuccessful because of unchanged or residual MR>2+. Immediately after device positioning, almost all the evaluated parameters showed a significant modification within each group with a reduction of anterior-posterior (AP-D) and bi-commissural (CC-D) MV diameters, MV annulus area and perimeter and an increase in tenting volume, tenting height and posterior mitral leaflet angle (PML α). Anterior mitral leaflet angle (AML α), sphericity index and aorto-mitral angle remained unchanged. We observed no significant difference in the sub-analysis between degenerative and all functional MR groups, although a different trend of parameters variation could be evidenced. Post-procedural tenting height with cut off of 5.5 mm was a predictor of procedural success (see fig.), while at univariate analysis basal AP-D in DMR group and sphericity index, PMLα and annulus height at baseline in the FMR group were all significantly correlated to the entity of MR reduction at discharge. Conclusions: Percutaneous edge-to-edge repair with MitraClip acutely changes the MV annular geometry in degenerative and both ventricular and atrial functional MR, with a different trend within each group. Post-procedural tenting height correlates with significant MR reduction at discharge, a promising marker that could be used in clinical practice for identification of MitraClip procedure success. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Mitral Valve Intervention
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.2646 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25489.xml