Value of tissue doppler indices for prediction of early atrial fibrillation recurrence after cardioversion. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Value of tissue doppler indices for prediction of early atrial fibrillation recurrence after cardioversion. (25th November 2020)
- Main Title:
- Value of tissue doppler indices for prediction of early atrial fibrillation recurrence after cardioversion
- Authors:
- Karaliute, R
Mizariene, V
Kazakevicius, T
Jurgaityte, J
Jureviciute, J
Baksyte, G
Kavoliuniene, A - Abstract:
- Abstract: Background: Spectral tissue Doppler-derived E/e' ratio has been proposed as the best parameter in the prediction of atrial fibrillation (AF). Although relaxation and contraction are equivalent parts of a continuous cardiac cycle, where systolic and diastolic abnormalities have a variable contribution to the left ventricle (LV) failure. A new doppler index, E/(e'×s') ratio, combining an index of diastolic function (E/e') and marker of systolic LV function (s'), has been confirmed as a good predictor of new-onset AF, although value of E/(e'×s') ratio to predict AF recurrence was not evaluated. Purpose: The aim of this study was to investigate whether E/(e'×s') may be better parameter than E/e' to predict AF recurrence after the electrical cardioversion (ECV) of persistent AF in patients with normal LV function. Methods: The prospective study included 77 patients with persistent AF with preserved LV ejection fraction (>50%) and successfully performed ECV. Plasma level of NT-proBNP was measured for all the patients before the ECV. Transthoracic echocardiography was performed within the first 24 hours after successful ECV. Primary outcome was the early (at 1 month) recurrence of AF. Results: At 1 month follow-up, 39 patients (50.6%) were in sinus rhythm. Binary logistic regression analysis showed that LV enddiastolic diameter >50 mm (HR 3.70, 95% CI 1.29–10.58, p=0.02), NT-proBNP >2000 ng/L (HR 3.28, 95% CI 1.01–10.71, p=0.04), E/e' (HR 1.74, 95% CI 1.27–2.39, p=0.001)Abstract: Background: Spectral tissue Doppler-derived E/e' ratio has been proposed as the best parameter in the prediction of atrial fibrillation (AF). Although relaxation and contraction are equivalent parts of a continuous cardiac cycle, where systolic and diastolic abnormalities have a variable contribution to the left ventricle (LV) failure. A new doppler index, E/(e'×s') ratio, combining an index of diastolic function (E/e') and marker of systolic LV function (s'), has been confirmed as a good predictor of new-onset AF, although value of E/(e'×s') ratio to predict AF recurrence was not evaluated. Purpose: The aim of this study was to investigate whether E/(e'×s') may be better parameter than E/e' to predict AF recurrence after the electrical cardioversion (ECV) of persistent AF in patients with normal LV function. Methods: The prospective study included 77 patients with persistent AF with preserved LV ejection fraction (>50%) and successfully performed ECV. Plasma level of NT-proBNP was measured for all the patients before the ECV. Transthoracic echocardiography was performed within the first 24 hours after successful ECV. Primary outcome was the early (at 1 month) recurrence of AF. Results: At 1 month follow-up, 39 patients (50.6%) were in sinus rhythm. Binary logistic regression analysis showed that LV enddiastolic diameter >50 mm (HR 3.70, 95% CI 1.29–10.58, p=0.02), NT-proBNP >2000 ng/L (HR 3.28, 95% CI 1.01–10.71, p=0.04), E/e' (HR 1.74, 95% CI 1.27–2.39, p=0.001) and E/(e'×s') ratios (HR 8.17, 95% CI 1.57–42.4, p=0.01) were significant predictors of AF early recurrence after ECV. When we developed multivariate models using these potential confounding factors. To minimize the problem of collinearity E/e'and E/(e'×s') were included in 2 separate models. Multivariate analysis identified that E/(e'×s') ratio and E/e' ratio in combination with LV enddiastolic diameter >49.3 mm and NT-proBNP >2000 ng/L are able to predict early AF recurrence after ECV in 74% and 79% cases, respectively. E/(e'×s') ratio showed higher contribution in the model to predict AF recurrence compared to E/e' ratio (for E/(e'×s') ratio HR 18.94, 95% CI 2.39–149.66, p=0.005; for E/e' ratio HR 1.95, 95% CI 1.31–2.91, p=0.001). On ROC analysis, the diagnostic accuracy of E/(e'×s') and E/e' ratios were found to have the largest areas under the curve (E/(e'×s') ratio, AUC = 0.71, p=0.002 and E/e' ratio, AUC = 0.75, p<0.0001) with an optimal E/(e'×s') ratio cut-off value of 1.15 (sensitivity 97%, specificity 58%) and E/e' ratio value of 8.79 (sensitivity 89%, specificity 41%) for predicting early recurrence of AF after ECV. Conclusions: Spectral tissue Doppler-derived ratios (E/(e'×s') and E/e') together with higher NTproBNP level and larger LV enddiastolic diameter predicted early AF recurrence after ECV. E/(e'×s') seems to be a more powerful predictor of AF early recurrence than E/e' ratio. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Atrial Fibrillation - Diagnostic Methods
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0544 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25488.xml