Early restenosis and late catch-up phenomenon after newer biodegradable- and durable-polymer drug-eluting stent implantations. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Early restenosis and late catch-up phenomenon after newer biodegradable- and durable-polymer drug-eluting stent implantations. (25th November 2020)
- Main Title:
- Early restenosis and late catch-up phenomenon after newer biodegradable- and durable-polymer drug-eluting stent implantations
- Authors:
- Masumoto, A
Ohya, M
Murai, R
Miura, K
Shimada, T
Amano, H
Kubo, S
Tada, T
Tanaka, H
Fuku, Y
Kadota, K - Abstract:
- Abstract: Background: It is yet to be known whether mechanisms underlying restenosis in newer-generation durable-polymer (DP) and biodegradable-polymer (BP) drug-eluting stents (DES) are different. Purpose: This study aims to assess the incidences and predictors of early restenosis and late catch-up phenomenon after newer-generation durable-polymer (DP) and biodegradable-polymer (BP) DES. Methods: Between 2010 and 2017, 13858 lesions in 6350 patients were treated with DES (4393 BP-DES, 9465 DP-DES). The early-term (within 1 year) and late-term (from 1 to 2 years) follow-up angiographies were scheduled. Late catch-up phenomenon was defined as in-stent restenosis (ISR) in lesions that evaded ISR within 1 year after stent implantation. ISR was defined as angiographic restenosis of more than 50%. Results: The mean patient age was 71 years, and 76.7% were male. Early-term angiographies were performed in 10955 lesions (79.0%). Of those without early-term ISR, late-term angiographies were performed in 7771 lesions (56.1%). The incidences of mid-term restenosis and late catch-up phenomenon were 6.6% and 3.9%, respectively. In the multivariate regression analyses, history of diabetes, hemodialysis and previous PCI were independent predictors of both early restenosis and late catch-up phenomenon. Also, some lesion characteristics such as chronic total occlusion, right coronary artery ostial lesion, small vessel (defined as reference diameter <2.5mm), long lesion (defined as lesionAbstract: Background: It is yet to be known whether mechanisms underlying restenosis in newer-generation durable-polymer (DP) and biodegradable-polymer (BP) drug-eluting stents (DES) are different. Purpose: This study aims to assess the incidences and predictors of early restenosis and late catch-up phenomenon after newer-generation durable-polymer (DP) and biodegradable-polymer (BP) DES. Methods: Between 2010 and 2017, 13858 lesions in 6350 patients were treated with DES (4393 BP-DES, 9465 DP-DES). The early-term (within 1 year) and late-term (from 1 to 2 years) follow-up angiographies were scheduled. Late catch-up phenomenon was defined as in-stent restenosis (ISR) in lesions that evaded ISR within 1 year after stent implantation. ISR was defined as angiographic restenosis of more than 50%. Results: The mean patient age was 71 years, and 76.7% were male. Early-term angiographies were performed in 10955 lesions (79.0%). Of those without early-term ISR, late-term angiographies were performed in 7771 lesions (56.1%). The incidences of mid-term restenosis and late catch-up phenomenon were 6.6% and 3.9%, respectively. In the multivariate regression analyses, history of diabetes, hemodialysis and previous PCI were independent predictors of both early restenosis and late catch-up phenomenon. Also, some lesion characteristics such as chronic total occlusion, right coronary artery ostial lesion, small vessel (defined as reference diameter <2.5mm), long lesion (defined as lesion length >30mm) and treatment of ISR lesion were independent predictors of both early restenosis and late catch-up phenomenon. Bifurcation lesion and heavily calcified lesion treated with rotablator were independent risk of early restenosis. Bypass graft lesion was an independent predictor of late catch-up phenomenon. Early restenosis was observed less frequently in DP-DES than in BP-DES (6.3% versus 7.4%, P=0.012). On the contrary, late catch-up phenomenon was observed more frequently in DP-DES than in BP-DES (4.3% versus 2.9%, P=0.026). Conclusions: Some lesion characteristics were independent predictors of early restenosis and late catch-up phenomenon after newer-generation DES implantation. The deployment of BP-DES resulted in more early restenosis and less late catch-up phenomenon compared to that of DP-DES. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Coronary Artery Disease: Treatment, Revascularization
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.1462 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25485.xml