Retrogated compressed sensing cine in one minute. (8th February 2021)
- Record Type:
- Journal Article
- Title:
- Retrogated compressed sensing cine in one minute. (8th February 2021)
- Main Title:
- Retrogated compressed sensing cine in one minute
- Authors:
- Longere, B
Grenier, L
Pagniez, J
Silvestri, V
Simeone, A
Hennicaux, J
Toupin, S
Pontana, F - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. PURPOSE Real-time compressed sensing cine (CSrt) provides reliable quantifications for both ventricles but impairs image quality . This aim of this study was to assess the accuracy of left (LV) and right ventricular (RV) volumes, ejection fraction and mass quantifications based on a retrogated segmented compressed sensing-fashioned accelerated 2D cine sequence (CSrg). Image quality was also evaluated. METHOD AND MATERIALS Thirty patients were enrolled. Each patient underwent the reference retrogated segmented steady-state free precession cine sequence (SSFPref), the first generation real-time CSrt cine and the segmented retrogated prototype CSrg sequence providing the same numbers and positions of slices. Functional parameters quantification was performed on SSFPref and CSrg images sets. Image quality was assessed for the three sequences by using edge sharpness which is an estimate of the edge spread function. RESULTS Mean scan times were: SSFPref = 512 ± 15 s, CSrt = 24 ± 5 s and CSrg = 58 ± 15 s. CSrg provided LV and RV functional parameters (end-systolic, end-diastolic, ejection fraction and LV mass) which were not significantly different from the one assessed with SSFPref (p > 0.05). Edge sharpness was significantly better with CSrg (0.083 ± 0.013 pixel-1) than with CSrt (0.070 ± 0.011 pixel-1; p = 0.0004) and not different from the reference techniques (0.075 ± 0.016 pixel-1; p = 0.0516). Inter andAbstract: Funding Acknowledgements: Type of funding sources: None. PURPOSE Real-time compressed sensing cine (CSrt) provides reliable quantifications for both ventricles but impairs image quality . This aim of this study was to assess the accuracy of left (LV) and right ventricular (RV) volumes, ejection fraction and mass quantifications based on a retrogated segmented compressed sensing-fashioned accelerated 2D cine sequence (CSrg). Image quality was also evaluated. METHOD AND MATERIALS Thirty patients were enrolled. Each patient underwent the reference retrogated segmented steady-state free precession cine sequence (SSFPref), the first generation real-time CSrt cine and the segmented retrogated prototype CSrg sequence providing the same numbers and positions of slices. Functional parameters quantification was performed on SSFPref and CSrg images sets. Image quality was assessed for the three sequences by using edge sharpness which is an estimate of the edge spread function. RESULTS Mean scan times were: SSFPref = 512 ± 15 s, CSrt = 24 ± 5 s and CSrg = 58 ± 15 s. CSrg provided LV and RV functional parameters (end-systolic, end-diastolic, ejection fraction and LV mass) which were not significantly different from the one assessed with SSFPref (p > 0.05). Edge sharpness was significantly better with CSrg (0.083 ± 0.013 pixel-1) than with CSrt (0.070 ± 0.011 pixel-1; p = 0.0004) and not different from the reference techniques (0.075 ± 0.016 pixel-1; p = 0.0516). Inter and intrarater variabilities demonstrated intraclass correlation coefficients over 0.96. CONCLUSION: CSrg cine provides in one minute an accurate quantification of LV and RV functional parameters without compromising the sharpness of myocardial boarders which was impaired by the first-generation real-time compressed sensing sequence. … (more)
- Is Part Of:
- European heart journal. Volume 22(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 22(2021)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2021-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-08
- Subjects:
- Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeaa356.261 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25473.xml