Self-navigated versus navigator-gated 3D MRI sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention. (8th February 2021)
- Record Type:
- Journal Article
- Title:
- Self-navigated versus navigator-gated 3D MRI sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention. (8th February 2021)
- Main Title:
- Self-navigated versus navigator-gated 3D MRI sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention
- Authors:
- Pamminger, M
Kranewitter, C
Kremser, C
Reindl, M
Reinstadler, SJ
Reiter, G
Piccini, D
Tiller, C
Holzknecht, M
Klug, G
Metzler, B
Mayr, A - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Preprocedural transcatheter aortic valve intervention (TAVI) evaluation requires reliable aortic root measurements for correct valve sizing. Purpose: To prospectively compare image-quality, reliability and graft sizing of a prototype self-navigated and a navigator-gated non-contrast three dimensional (3D) whole-heart magnetic-resonance-angiography (MRA) sequence with computed-tomography-angiography (CTA) for planning transcatheter-aortic-valve-intervention (TAVI). Methods: Self- and navigator-gated 1.5T MRA were performed in 27 patients (aged 83 ± 5 years, 41% male) for aortic root sizing and coronary ostia height measurements; 15 (56%) patients underwent additional CTA. Subjective-image quality was graded on a 4-point Likert scale, objective MRA image-quality was assessed by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Continuous MRA and CTA measurements were analyzed with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results: Median image-quality as rated by two observers was 1.5 [interquartile range (IQR) 1-3] for self-navigated MRA and 1 [IQR 1-2] for navigator-gated MRA (p = 0.059). SNR and CNR were comparable between MRA sequences (p = 0.471 and 0.445, respectively). Acquisition time was shorter for self-navigated MRA compared to navigator-gated MRA (5.5 ± 1 minutes vs, 6.5 ± 2 minutes, p = 0.029). Inter-observer correlation of aortic rootAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Preprocedural transcatheter aortic valve intervention (TAVI) evaluation requires reliable aortic root measurements for correct valve sizing. Purpose: To prospectively compare image-quality, reliability and graft sizing of a prototype self-navigated and a navigator-gated non-contrast three dimensional (3D) whole-heart magnetic-resonance-angiography (MRA) sequence with computed-tomography-angiography (CTA) for planning transcatheter-aortic-valve-intervention (TAVI). Methods: Self- and navigator-gated 1.5T MRA were performed in 27 patients (aged 83 ± 5 years, 41% male) for aortic root sizing and coronary ostia height measurements; 15 (56%) patients underwent additional CTA. Subjective-image quality was graded on a 4-point Likert scale, objective MRA image-quality was assessed by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Continuous MRA and CTA measurements were analyzed with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results: Median image-quality as rated by two observers was 1.5 [interquartile range (IQR) 1-3] for self-navigated MRA and 1 [IQR 1-2] for navigator-gated MRA (p = 0.059). SNR and CNR were comparable between MRA sequences (p = 0.471 and 0.445, respectively). Acquisition time was shorter for self-navigated MRA compared to navigator-gated MRA (5.5 ± 1 minutes vs, 6.5 ± 2 minutes, p = 0.029). Inter-observer correlation of aortic root measurements was high to very high for both self- and navigator-gated MRA (r = 0.75 to 0.94 and r = 0.85 to 0.96, respectively, all p < 0.0001). Theoretical prosthetic valve sizing of self-navigated MRA and CTA was equivalent (κ=1). However, in four patients (15%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on self-navigated MRA. Conclusion: Self-navigated MRA enables aortic annulus TAVI measurements without significant difference to navigator-gated MRA at shortened acquisition time. Prosthesis sizing by self-navigated MRA measurements is equivalent to navigator-gated MRA and CTA-based choice. … (more)
- Is Part Of:
- European heart journal. Volume 22(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 22(2021)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2021-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-08
- Subjects:
- Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeaa356.319 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25439.xml