False-negative malaria rapid diagnostic test results and their impact on community-based malaria surveys in sub-Saharan Africa. Issue 4 (29th July 2019)
- Record Type:
- Journal Article
- Title:
- False-negative malaria rapid diagnostic test results and their impact on community-based malaria surveys in sub-Saharan Africa. Issue 4 (29th July 2019)
- Main Title:
- False-negative malaria rapid diagnostic test results and their impact on community-based malaria surveys in sub-Saharan Africa
- Authors:
- Watson, Oliver J
Sumner, Kelsey Marie
Janko, Mark
Goel, Varun
Winskill, Peter
Slater, Hannah C
Ghani, Azra
Meshnick, Steven R
Parr, Jonathan B - Abstract:
- Abstract : Surveillance and diagnosis of Plasmodium falciparum malaria relies predominantly on rapid diagnostic tests (RDT). However, false-negative (FN) RDT results are known to occur for a variety of reasons, including operator error, poor storage conditions, pfhrp2/3 gene deletions, poor performance of specific RDT brands and lots, and low-parasite density infections. We used RDT and microscopy results from 85 000 children enrolled in Demographic Health Surveys and Malaria Indicator Surveys from 2009 to 2015 across 19 countries to explore the distribution of and risk factors for FN-RDTs in sub-Saharan Africa, where malaria's impact is greatest. We sought to (1) identify spatial and demographic patterns of FN-RDT results, defined as a negative RDT but positive gold standard microscopy test, and (2) estimate the percentage of infections missed within community-based malaria surveys due to FN-RDT results. Across all studies, 19.9% (95% CI 19.0% to 20.9%) of microscopy-positive subjects were negative by RDT. The distribution of FN-RDT results was spatially heterogeneous. The variance in FN-RDT results was best explained by the prevalence of malaria, with an increase in FN-RDT results observed at lower transmission intensities, among younger subjects, and in urban areas. The observed proportion of FN-RDT results was not predicted by differences in RDT brand or lot performance alone. These findings characterise how the probability of detection by RDTs varies in differentAbstract : Surveillance and diagnosis of Plasmodium falciparum malaria relies predominantly on rapid diagnostic tests (RDT). However, false-negative (FN) RDT results are known to occur for a variety of reasons, including operator error, poor storage conditions, pfhrp2/3 gene deletions, poor performance of specific RDT brands and lots, and low-parasite density infections. We used RDT and microscopy results from 85 000 children enrolled in Demographic Health Surveys and Malaria Indicator Surveys from 2009 to 2015 across 19 countries to explore the distribution of and risk factors for FN-RDTs in sub-Saharan Africa, where malaria's impact is greatest. We sought to (1) identify spatial and demographic patterns of FN-RDT results, defined as a negative RDT but positive gold standard microscopy test, and (2) estimate the percentage of infections missed within community-based malaria surveys due to FN-RDT results. Across all studies, 19.9% (95% CI 19.0% to 20.9%) of microscopy-positive subjects were negative by RDT. The distribution of FN-RDT results was spatially heterogeneous. The variance in FN-RDT results was best explained by the prevalence of malaria, with an increase in FN-RDT results observed at lower transmission intensities, among younger subjects, and in urban areas. The observed proportion of FN-RDT results was not predicted by differences in RDT brand or lot performance alone. These findings characterise how the probability of detection by RDTs varies in different transmission settings and emphasise the need for careful interpretation of prevalence estimates based on surveys employing RDTs alone. Further studies are needed to characterise the cost-effectiveness of improved malaria diagnostics (eg, PCR or highly sensitive RDTs) in community-based surveys, especially in regions of low transmission intensity or high urbanicity. … (more)
- Is Part Of:
- BMJ global health. Volume 4:Issue 4(2019)
- Journal:
- BMJ global health
- Issue:
- Volume 4:Issue 4(2019)
- Issue Display:
- Volume 4, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 4
- Issue:
- 4
- Issue Sort Value:
- 2019-0004-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-07-29
- Subjects:
- malaria diagnosis -- rapid diagnostic tests -- RDTs -- pfhrp2 -- pfhrp2 deletion -- Plasmodium falciparum -- mathematical modelling -- mapping
World health -- Periodicals
362.105 - Journal URLs:
- http://www.bmj.com/archive ↗
http://gh.bmj.com/ ↗ - DOI:
- 10.1136/bmjgh-2019-001582 ↗
- Languages:
- English
- ISSNs:
- 2059-7908
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25438.xml