A Digital Calibration Method for a MEMS Accelerometer based on Harmonic Self-Test. (April 2020)
- Record Type:
- Journal Article
- Title:
- A Digital Calibration Method for a MEMS Accelerometer based on Harmonic Self-Test. (April 2020)
- Main Title:
- A Digital Calibration Method for a MEMS Accelerometer based on Harmonic Self-Test
- Authors:
- Chen, Dongliang
Liu, Xiaowei
Yin, Liang
QiangFu, - Abstract:
- Abstract: This paper proposes a digital calibration method for electromechanical closed-loop MEMS accelerometer. The method based on a harmonic self-test mechanism, in which the MEMS structure is excited by an on-chip generated electrostatic force and the corresponding harmonic distortion could be captured and analysed as an indicator of structure mismatch. According the harmonic distortion level, the mismatch could be calibrated out by the electrical signal on-chip. The whole exciting and calibrating procedure is realized in digital domain. Thus, not only the area and power consumption are reduced, but also the flexibility and robustness of the procedure is enhanced.
- Is Part Of:
- Journal of physics. Volume 1520(2020)
- Journal:
- Journal of physics
- Issue:
- Volume 1520(2020)
- Issue Display:
- Volume 1520, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 1520
- Issue:
- 1
- Issue Sort Value:
- 2020-1520-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- Physics -- Congresses
530.5 - Journal URLs:
- http://www.iop.org/EJ/journal/1742-6596 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1742-6596/1520/1/012008 ↗
- Languages:
- English
- ISSNs:
- 1742-6588
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5036.223000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25418.xml