Phase2Phase: Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging. Issue 12 (December 2021)
- Record Type:
- Journal Article
- Title:
- Phase2Phase: Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging. Issue 12 (December 2021)
- Main Title:
- Phase2Phase
- Authors:
- Eldeniz, Cihat
Gan, Weijie
Chen, Sihao
Fraum, Tyler J.
Ludwig, Daniel R.
Yan, Yan
Liu, Jiaming
Vahle, Thomas
Krishnamurthy, Uday
Kamilov, Ulugbek S.
An, Hongyu - Abstract:
- Abstract : Objectives: Respiratory binning of free-breathing magnetic resonance imaging data reduces motion blurring; however, it exacerbates noise and introduces severe artifacts due to undersampling. Deep neural networks can remove artifacts and noise but usually require high-quality ground truth images for training. This study aimed to develop a network that can be trained without this requirement. Materials and Methods: This retrospective study was conducted on 33 participants enrolled between November 2016 and June 2019. Free-breathing magnetic resonance imaging was performed using a radial acquisition. Self-navigation was used to bin the k-space data into 10 respiratory phases. To simulate short acquisitions, subsets of radial spokes were used in reconstructing images with multicoil nonuniform fast Fourier transform (MCNUFFT), compressed sensing (CS), and 2 deep learning methods: UNet3DPhase and Phase2Phase (P2P). UNet3DPhase was trained using a high-quality ground truth, whereas P2P was trained using noisy images with streaking artifacts. Two radiologists blinded to the reconstruction methods independently reviewed the sharpness, contrast, and artifact-freeness of the end-expiration images reconstructed from data collected at 16% of the Nyquist sampling rate. The generalized estimating equation method was used for statistical comparison. Motion vector fields were derived to examine the respiratory motion range of 4-dimensional images reconstructed using differentAbstract : Objectives: Respiratory binning of free-breathing magnetic resonance imaging data reduces motion blurring; however, it exacerbates noise and introduces severe artifacts due to undersampling. Deep neural networks can remove artifacts and noise but usually require high-quality ground truth images for training. This study aimed to develop a network that can be trained without this requirement. Materials and Methods: This retrospective study was conducted on 33 participants enrolled between November 2016 and June 2019. Free-breathing magnetic resonance imaging was performed using a radial acquisition. Self-navigation was used to bin the k-space data into 10 respiratory phases. To simulate short acquisitions, subsets of radial spokes were used in reconstructing images with multicoil nonuniform fast Fourier transform (MCNUFFT), compressed sensing (CS), and 2 deep learning methods: UNet3DPhase and Phase2Phase (P2P). UNet3DPhase was trained using a high-quality ground truth, whereas P2P was trained using noisy images with streaking artifacts. Two radiologists blinded to the reconstruction methods independently reviewed the sharpness, contrast, and artifact-freeness of the end-expiration images reconstructed from data collected at 16% of the Nyquist sampling rate. The generalized estimating equation method was used for statistical comparison. Motion vector fields were derived to examine the respiratory motion range of 4-dimensional images reconstructed using different methods. Results: A total of 15 healthy participants and 18 patients with hepatic malignancy (50 ± 15 years, 6 women) were enrolled. Both reviewers found that the UNet3DPhase and P2P images had higher contrast ( P < 0.01) and fewer artifacts ( P < 0.01) than the CS images. The UNet3DPhase and P2P images were reported to be sharper than the CS images by 1 reviewer ( P < 0.01) but not by the other reviewer ( P = 0.22, P = 0.18). UNet3DPhase and P2P were similar in sharpness and contrast, whereas UNet3DPhase had fewer artifacts ( P < 0.01). The motion vector lengths for the MCNUFFT800 and P2P800 images were comparable (10.5 ± 4.2 mm and 9.9 ± 4.0 mm, respectively), whereas both were significantly larger than CS2000 (7.0 ± 3.9 mm; P < 0.0001) and UNnet3DPhase800 (6.9 ± 3.2; P < 0.0001) images. Conclusions: Without a ground truth, P2P can reconstruct sharp, artifact-free, and high-contrast respiratory motion-resolved images from highly undersampled data. Unlike the CS and UNet3DPhase methods, P2P did not artificially reduce the respiratory motion range. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Investigative radiology. Volume 56:Issue 12(2021)
- Journal:
- Investigative radiology
- Issue:
- Volume 56:Issue 12(2021)
- Issue Display:
- Volume 56, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 12
- Issue Sort Value:
- 2021-0056-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- noise-to-noise -- free-breathing MRI -- CAPTURE -- deep learning -- no ground truth -- artifact reduction
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000792 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25383.xml