Impact of Integrating Rumke Statistics to Assist with Choosing Between Automated Hematology Analyzer Differentials vs Manual Differentials. (1st January 2017)
- Record Type:
- Journal Article
- Title:
- Impact of Integrating Rumke Statistics to Assist with Choosing Between Automated Hematology Analyzer Differentials vs Manual Differentials. (1st January 2017)
- Main Title:
- Impact of Integrating Rumke Statistics to Assist with Choosing Between Automated Hematology Analyzer Differentials vs Manual Differentials
- Authors:
- Stephens, Laura
Hintz-Prunty, Wendy
Bengtsson, Hans-Inge
Proudfoot, James A
Patel, Sandip Pravin
Broome, H Elizabeth - Abstract:
- Abstract: Background: To optimize precision of nucleated blood cell counting, the clinical laboratory scientist should post the automated differential rather than the manual differential if the former is within the 95% CI of the latter, as determined by the "Rumke statistic." The objective of this study was to determine the potential impact of real-time, computer-assisted use of Rumke statistics for more judicious use of the automated vs digitally imaged, manual differential. Methods: Complete blood counts with automated differentials produced by a XE5000™ hematology analyzer (Sysmex) were compared with both the DM96 (CellaVision™ AB) preclassification differentials and the posted reclassified manual differentials, using the Rumke 95% CIs as calculated using the Clopper-Pearson method. Results: A total of 44.7% of manual differentials had no statistical or clinical justification over the automated differential. In addition, 31.1% of manual differentials had statistical discrepancies between the instrument absolute neutrophil count (IANC) and manual absolute neutrophil count (ANC). Nineteen of these IANC/manual ANC discrepant samples had ANCs below 1500/μL, a decision level for cancer treatment. Holding the IANC when it is less than 2000/μL until after manual smear review would have prevented the posting of any IANC vs manual ANC discrepant results at the 1500/μL ANC decision threshold. Conclusions: A real-time operator alert concerning the statistical identity of imagingAbstract: Background: To optimize precision of nucleated blood cell counting, the clinical laboratory scientist should post the automated differential rather than the manual differential if the former is within the 95% CI of the latter, as determined by the "Rumke statistic." The objective of this study was to determine the potential impact of real-time, computer-assisted use of Rumke statistics for more judicious use of the automated vs digitally imaged, manual differential. Methods: Complete blood counts with automated differentials produced by a XE5000™ hematology analyzer (Sysmex) were compared with both the DM96 (CellaVision™ AB) preclassification differentials and the posted reclassified manual differentials, using the Rumke 95% CIs as calculated using the Clopper-Pearson method. Results: A total of 44.7% of manual differentials had no statistical or clinical justification over the automated differential. In addition, 31.1% of manual differentials had statistical discrepancies between the instrument absolute neutrophil count (IANC) and manual absolute neutrophil count (ANC). Nineteen of these IANC/manual ANC discrepant samples had ANCs below 1500/μL, a decision level for cancer treatment. Holding the IANC when it is less than 2000/μL until after manual smear review would have prevented the posting of any IANC vs manual ANC discrepant results at the 1500/μL ANC decision threshold. Conclusions: A real-time operator alert concerning the statistical identity of imaging device differentials vs automated differentials could have reduced manual differentials by nearly 45%. Not posting unnecessary manual differentials for the cases with IANC/manual ANC discrepancies would have likely reduced clinical error/confusion. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 1:Number 4(2017)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 1:Number 4(2017)
- Issue Display:
- Volume 1, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 1
- Issue:
- 4
- Issue Sort Value:
- 2017-0001-0004-0000
- Page Start:
- 357
- Page End:
- 364
- Publication Date:
- 2017-01-01
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2016.021030 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25401.xml