INCREASED EXPOSURE TO X-RAYS DURING CORONARY ANGIOGRAPHY AND PERCUTANEOUS CORONARY INTERVENTIONS ASSOCIATED WITH FRACTIONAL FLOW RESERVE MEASUREMENT AND ENDOCORONARY IMAGING TECHNIQUES. Issue 1 (6th May 2021)
- Record Type:
- Journal Article
- Title:
- INCREASED EXPOSURE TO X-RAYS DURING CORONARY ANGIOGRAPHY AND PERCUTANEOUS CORONARY INTERVENTIONS ASSOCIATED WITH FRACTIONAL FLOW RESERVE MEASUREMENT AND ENDOCORONARY IMAGING TECHNIQUES. Issue 1 (6th May 2021)
- Main Title:
- INCREASED EXPOSURE TO X-RAYS DURING CORONARY ANGIOGRAPHY AND PERCUTANEOUS CORONARY INTERVENTIONS ASSOCIATED WITH FRACTIONAL FLOW RESERVE MEASUREMENT AND ENDOCORONARY IMAGING TECHNIQUES
- Authors:
- Bensaid, Réda
Georges, Jean-Louis
Angoulvant, Denis
Chassaing, Stephan
Deballon, Ronan
Marcollet, Pierre
Albert, Franck
Fichaux, Olivier
Bar, Olivier
Rangé, Grégoire - Abstract:
- Abstract: Growing use of fractional flow reserve (FFR) and intracoronary imaging techniques by optical coherence tomography or intravascular ultrasound has raised concerns about additional exposure during coronary angiography and percutaneous coronary interventions (PCIs). Using data from the prospective CRAC-France PCI Prospective Multicentre registry, we sought to evaluate the effect of these new techniques on the radiation dose to patients undergoing coronary procedures. Data on Kerma Area Product ( P KA ), total air kerma (KAr ) and fluoroscopy time from 42 182 coronary procedures were retrospectively compared, using multivariable linear regression, according to whether they included FFR and intracoronary imaging. In coronary angiography, FFR was associated with longer fluoroscopy time and higher P KA (21.0 vs. 18.9 Gy.cm 2 ) and KAr (372 vs. 299 mGy) (all p < 0.001). Intracoronary imaging was associated with longer fluoroscopy time, higher contrast volume (both p < 0.001), lower P KA (18.3 vs. 19.0 Gy.cm 2, p = 0.02) and similar KAr . In PCI, FFR was associated with a moderate increase in KAr (682 vs. 626 mGy, p < 0.01) but not P KA (35.9 vs. 33.7 Gy.cm 2, p = 0.34). For intracoronary imaging, there were no differences between groups, except for contrast volume. Increased patient exposure associated with FFR and intracoronary imaging is moderate in diagnostic coronary angiography and minimal or none in PCI, provided optimization techniques are used. It should notAbstract: Growing use of fractional flow reserve (FFR) and intracoronary imaging techniques by optical coherence tomography or intravascular ultrasound has raised concerns about additional exposure during coronary angiography and percutaneous coronary interventions (PCIs). Using data from the prospective CRAC-France PCI Prospective Multicentre registry, we sought to evaluate the effect of these new techniques on the radiation dose to patients undergoing coronary procedures. Data on Kerma Area Product ( P KA ), total air kerma (KAr ) and fluoroscopy time from 42 182 coronary procedures were retrospectively compared, using multivariable linear regression, according to whether they included FFR and intracoronary imaging. In coronary angiography, FFR was associated with longer fluoroscopy time and higher P KA (21.0 vs. 18.9 Gy.cm 2 ) and KAr (372 vs. 299 mGy) (all p < 0.001). Intracoronary imaging was associated with longer fluoroscopy time, higher contrast volume (both p < 0.001), lower P KA (18.3 vs. 19.0 Gy.cm 2, p = 0.02) and similar KAr . In PCI, FFR was associated with a moderate increase in KAr (682 vs. 626 mGy, p < 0.01) but not P KA (35.9 vs. 33.7 Gy.cm 2, p = 0.34). For intracoronary imaging, there were no differences between groups, except for contrast volume. Increased patient exposure associated with FFR and intracoronary imaging is moderate in diagnostic coronary angiography and minimal or none in PCI, provided optimization techniques are used. It should not be a limitation on the use of these techniques given the important additional information they provide. … (more)
- Is Part Of:
- Radiation protection dosimetry. Volume 194:Issue 1(2021)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 194:Issue 1(2021)
- Issue Display:
- Volume 194, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 194
- Issue:
- 1
- Issue Sort Value:
- 2021-0194-0001-0000
- Page Start:
- 18
- Page End:
- 26
- Publication Date:
- 2021-05-06
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncab065 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25373.xml