Reliability and minimal detectable change of a new treadmill-based progressive workload incremental test to measure cardiorespiratory fitness in manual wheelchair users. (2nd November 2017)
- Record Type:
- Journal Article
- Title:
- Reliability and minimal detectable change of a new treadmill-based progressive workload incremental test to measure cardiorespiratory fitness in manual wheelchair users. (2nd November 2017)
- Main Title:
- Reliability and minimal detectable change of a new treadmill-based progressive workload incremental test to measure cardiorespiratory fitness in manual wheelchair users
- Authors:
- Gauthier, Cindy
Arel, Jasmine
Brosseau, Rachel
Hicks, Audrey L.
Gagnon, Dany H. - Abstract:
- Abstract : Background: Cardiorespiratory fitness training is commonly provided to manual wheelchair users (MWUs) in rehabilitation and physical activity programs, emphasizing the need for a reliable task-specific incremental wheelchair propulsion test. Objective: Quantifying test-retest reliability and minimal detectable change (MDC) of key cardiorespiratory fitness measures following performance of a newly developed continuous treadmill-based wheelchair propulsion test (WPTTreadmill ). Methods: Twenty-five MWUs completed the WPTTreadmill on two separate occasions within one week. During these tests, participants continuously propelled their wheelchair on a motorized treadmill while the exercise intensity was gradually increased every minute until exhaustion by changing the slope and/or speed according to a standardized protocol. Peak oxygen consumption (VO2peak ), carbon dioxide production (VCO2peak ), respiratory exchange ratio (RERpeak ), minute ventilation (VEpeak ) and heart rate (HRpeak ) were computed. Time to exhaustion (TTE) and number of increments completed were also measured. Intra-class correlation coefficients (ICC) were calculated to determine test-retest reliability. Standard error of measurement (SEM) and MDC90% values were calculated. Results: Excellent test-retest reliability was reached for almost all outcome measures (ICC=0.91-0.76), except for RERpeak (ICC=0.58), which reached good reliability. TTE (ICC=0.89) and number of increments (ICC=0.91) alsoAbstract : Background: Cardiorespiratory fitness training is commonly provided to manual wheelchair users (MWUs) in rehabilitation and physical activity programs, emphasizing the need for a reliable task-specific incremental wheelchair propulsion test. Objective: Quantifying test-retest reliability and minimal detectable change (MDC) of key cardiorespiratory fitness measures following performance of a newly developed continuous treadmill-based wheelchair propulsion test (WPTTreadmill ). Methods: Twenty-five MWUs completed the WPTTreadmill on two separate occasions within one week. During these tests, participants continuously propelled their wheelchair on a motorized treadmill while the exercise intensity was gradually increased every minute until exhaustion by changing the slope and/or speed according to a standardized protocol. Peak oxygen consumption (VO2peak ), carbon dioxide production (VCO2peak ), respiratory exchange ratio (RERpeak ), minute ventilation (VEpeak ) and heart rate (HRpeak ) were computed. Time to exhaustion (TTE) and number of increments completed were also measured. Intra-class correlation coefficients (ICC) were calculated to determine test-retest reliability. Standard error of measurement (SEM) and MDC90% values were calculated. Results: Excellent test-retest reliability was reached for almost all outcome measures (ICC=0.91-0.76), except for RERpeak (ICC=0.58), which reached good reliability. TTE (ICC=0.89) and number of increments (ICC=0.91) also reached excellent test-retest reliability. For the main outcome measures (VO2peak and TTE), absolute SEM was 2.27 mL/kg/min and 0.76 minutes, respectively and absolute MDC90% was 5.30 mL/kg/min and 1.77 minutes, respectively. Conclusion: The WPTTreadmill is a reliable test to assess cardiorespiratory fitness among MWUs. TTE and number of increments could be used as reliable outcome measures when VO2 measurement is not possible. … (more)
- Is Part Of:
- Journal of spinal cord medicine. Volume 40:Number 6(2017:Nov.)
- Journal:
- Journal of spinal cord medicine
- Issue:
- Volume 40:Number 6(2017:Nov.)
- Issue Display:
- Volume 40, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 40
- Issue:
- 6
- Issue Sort Value:
- 2017-0040-0006-0000
- Page Start:
- 759
- Page End:
- 767
- Publication Date:
- 2017-11-02
- Subjects:
- Wheelchairs -- Exercise test -- Rehabilitation -- Cardiorespiratory fitness
Spinal cord -- Wounds and injuries -- Periodicals
Spinal cord -- Diseases -- Periodicals
616.8305 - Journal URLs:
- http://www.ingentaconnect.com/content/maney/scm ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/350/ ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1080/10790268.2017.1369213 ↗
- Languages:
- English
- ISSNs:
- 1079-0268
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.181500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25371.xml