Accuracy of Spinal Anesthesia Drug Concentrations in Mixtures Prepared by Anesthetists. Issue 8 (7th December 2022)
- Record Type:
- Journal Article
- Title:
- Accuracy of Spinal Anesthesia Drug Concentrations in Mixtures Prepared by Anesthetists. Issue 8 (7th December 2022)
- Main Title:
- Accuracy of Spinal Anesthesia Drug Concentrations in Mixtures Prepared by Anesthetists
- Authors:
- Heesen, Michael
Steuer, Christian
Wiedemeier, Peter
Schwappach, David - Abstract:
- Abstract : Objective: Medication errors include the indirect dosing of drugs. For spinal anesthesia mixtures of local anesthetics, opioids are drawn from ampoules and combined in a syringe, according to clinical practice. We set out to determine the accuracy of the drug mixtures. Methods: Physicians of our department were invited to prepare the mixture used for spinal anesthesia for cesarean section, consisting of 10-mg hyperbaric bupivacaine (2-mL volume), 20-μg fentanyl (0.4-mL volume), and 100-μg morphine (0.1-mL volume). Concentrations of these drugs were determined by means of high performance liquid chromatography. Interindividual and intraindividual variations were assessed. Results: We analyzed 96 samples from 31 physicians. Fifty-one percent of the measured bupivacaine concentrations were in ±10% deviation range of the intended concentration; 17% of the fentanyl and 24% of the morphine concentrations were in this range. A total of 2.1% of the samples had a bupivacaine concentration corresponding to a dose of 8 mg or less, and 11.5% of the samples had a morphine concentration corresponding to a dose of 150 μg or greater. Intraindividual variations were 10.9% for bupivacaine, 24.7% for fentanyl, and 38.9% for morphine. Conclusions: Our results show a high deviation of the obtained from the intended concentrations. Two percent of the samples had bupivacaine concentrations that probably resulted into an insufficient analgesia, and 11% of the samples had morphineAbstract : Objective: Medication errors include the indirect dosing of drugs. For spinal anesthesia mixtures of local anesthetics, opioids are drawn from ampoules and combined in a syringe, according to clinical practice. We set out to determine the accuracy of the drug mixtures. Methods: Physicians of our department were invited to prepare the mixture used for spinal anesthesia for cesarean section, consisting of 10-mg hyperbaric bupivacaine (2-mL volume), 20-μg fentanyl (0.4-mL volume), and 100-μg morphine (0.1-mL volume). Concentrations of these drugs were determined by means of high performance liquid chromatography. Interindividual and intraindividual variations were assessed. Results: We analyzed 96 samples from 31 physicians. Fifty-one percent of the measured bupivacaine concentrations were in ±10% deviation range of the intended concentration; 17% of the fentanyl and 24% of the morphine concentrations were in this range. A total of 2.1% of the samples had a bupivacaine concentration corresponding to a dose of 8 mg or less, and 11.5% of the samples had a morphine concentration corresponding to a dose of 150 μg or greater. Intraindividual variations were 10.9% for bupivacaine, 24.7% for fentanyl, and 38.9% for morphine. Conclusions: Our results show a high deviation of the obtained from the intended concentrations. Two percent of the samples had bupivacaine concentrations that probably resulted into an insufficient analgesia, and 11% of the samples had morphine concentrations that, according to guidelines, would require a longer monitoring period than with the intended dose. … (more)
- Is Part Of:
- Journal of patient safety. Volume 18:Issue 8(2022)
- Journal:
- Journal of patient safety
- Issue:
- Volume 18:Issue 8(2022)
- Issue Display:
- Volume 18, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 18
- Issue:
- 8
- Issue Sort Value:
- 2022-0018-0008-0000
- Page Start:
- e1226
- Page End:
- e1230
- Publication Date:
- 2022-12-07
- Subjects:
- medication error -- spinal anesthesia -- bupivacaine -- fentanyl -- morphine
Patients -- Safety measures -- Periodicals
Medicine -- Practice -- Safety measures -- Periodicals
Medical errors -- Prevention -- Periodicals
610.289 - Journal URLs:
- http://journals.lww.com/journalpatientsafety/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PTS.0000000000001061 ↗
- Languages:
- English
- ISSNs:
- 1549-8417
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.008000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25373.xml