Feasibility and efficacy of intraoperative neural monitoring in remote access robotic and endoscopic thyroidectomy. (April 2020)
- Record Type:
- Journal Article
- Title:
- Feasibility and efficacy of intraoperative neural monitoring in remote access robotic and endoscopic thyroidectomy. (April 2020)
- Main Title:
- Feasibility and efficacy of intraoperative neural monitoring in remote access robotic and endoscopic thyroidectomy
- Authors:
- Ji, Yong Bae
Ko, Seok Hwa
Song, Chang Myeon
Sung, Eui Suk
Lee, Byung-Joo
Wu, Che-Wei
Chiang, Feng-Yu
Tae, Kyung - Abstract:
- Highlights: We evaluated the efficacy of IONM in remote access thyroidectomy. The success rate of IONM was lower compared to conventional thyroidectomy. Obtaining the vagus nerve EMG signal was relatively difficult. It was difficult to follow the troubleshooting algorithm. IONM helps confirm the RLN and predict nerve function. Abstract: Objectives: We performed this study to assess the feasibility and efficacy of intraoperative neural monitoring (IONM) in remote access robotic and endoscopic thyroidectomy. Materials and methods: We studied 104 consecutive patients (122 nerves at risk, NARs) who underwent robotic or endoscopic thyroidectomy via a postauricular facelift approach or transoral approach while performing intermittent IONM. Results: IONM was successful in 86/104 patients (82.7%). The success rate was significantly lower in the first 15 cases using a transoral approach than in the subsequent cases (7/15 vs. 41/43, p < 0.001). The standard IONM procedure (obtaining V1/R1/R2/V2 signals) was performed on 32/42 NARs (76.2%) undergoing thyroidectomy via a facelift approach and 10/58 NARs (17.2%) undergoing thyroidectomy via a transoral approach (p < 0.001). Loss of signal occurred in 6/100 NARs in 86 patients receiving successful IONM. Of these 6 LOS, 5 were false positives, and 1 was a true positive. A false negative occurred in 1/100 NARs. The sensitivity, specificity, positive and negative predictive values of IONM were 50.0%, 94.9% 16.7% and 98.9%, respectively.Highlights: We evaluated the efficacy of IONM in remote access thyroidectomy. The success rate of IONM was lower compared to conventional thyroidectomy. Obtaining the vagus nerve EMG signal was relatively difficult. It was difficult to follow the troubleshooting algorithm. IONM helps confirm the RLN and predict nerve function. Abstract: Objectives: We performed this study to assess the feasibility and efficacy of intraoperative neural monitoring (IONM) in remote access robotic and endoscopic thyroidectomy. Materials and methods: We studied 104 consecutive patients (122 nerves at risk, NARs) who underwent robotic or endoscopic thyroidectomy via a postauricular facelift approach or transoral approach while performing intermittent IONM. Results: IONM was successful in 86/104 patients (82.7%). The success rate was significantly lower in the first 15 cases using a transoral approach than in the subsequent cases (7/15 vs. 41/43, p < 0.001). The standard IONM procedure (obtaining V1/R1/R2/V2 signals) was performed on 32/42 NARs (76.2%) undergoing thyroidectomy via a facelift approach and 10/58 NARs (17.2%) undergoing thyroidectomy via a transoral approach (p < 0.001). Loss of signal occurred in 6/100 NARs in 86 patients receiving successful IONM. Of these 6 LOS, 5 were false positives, and 1 was a true positive. A false negative occurred in 1/100 NARs. The sensitivity, specificity, positive and negative predictive values of IONM were 50.0%, 94.9% 16.7% and 98.9%, respectively. Conclusions: The failure rate of IONM in remote access thyroidectomy is relatively high and following the standard IONM procedure is also relatively difficult. However, IONM is more helpful in confirming the recurrent laryngeal nerve (RLN) and predicting that it is functional in the limited working space available than it is in conventional thyroid surgery. … (more)
- Is Part Of:
- Oral oncology. Volume 103(2020)
- Journal:
- Oral oncology
- Issue:
- Volume 103(2020)
- Issue Display:
- Volume 103, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 103
- Issue:
- 2020
- Issue Sort Value:
- 2020-0103-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- Intraoperative neuromonitoring -- Recurrent laryngeal nerve injury -- Robotic thyroidectomy -- Endoscopic thyroidectomy -- Remote access thyroidectomy
Mouth -- Cancer -- Periodicals
Mouth -- Tumors -- Periodicals
Mouth Diseases -- Periodicals
Mouth Neoplasms -- Periodicals
Bouche -- Cancer -- Périodiques
Bouche -- Tumeurs -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9943105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13688375 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13688375 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.oraloncology.2020.104617 ↗
- Languages:
- English
- ISSNs:
- 1368-8375
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6277.592000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25361.xml