Effect of switching from intermittently scanned to real-time continuous glucose monitoring in adults with type 1 diabetes: 24-month results from the randomised ALERTT1 trial. Issue 2 (February 2023)
- Record Type:
- Journal Article
- Title:
- Effect of switching from intermittently scanned to real-time continuous glucose monitoring in adults with type 1 diabetes: 24-month results from the randomised ALERTT1 trial. Issue 2 (February 2023)
- Main Title:
- Effect of switching from intermittently scanned to real-time continuous glucose monitoring in adults with type 1 diabetes: 24-month results from the randomised ALERTT1 trial
- Authors:
- Visser, Margaretha M
Charleer, Sara
Fieuws, Steffen
De Block, Christophe
Hilbrands, Robert
Van Huffel, Liesbeth
Maes, Toon
Vanhaverbeke, Gerd
Dirinck, Eveline
Myngheer, Nele
Vercammen, Chris
Nobels, Frank
Keymeulen, Bart
Mathieu, Chantal
Gillard, Pieter - Abstract:
- Summary: Background: Comparing Continuous With Flash Glucose Monitoring In Adults With Type 1 Diabetes (ALERTT1) examined whether switching from first-generation intermittently scanned continuous glucose monitoring (isCGM) without alerts to real-time continuous glucose monitoring (rtCGM) with alert functionality offers additional benefits to adults with type 1 diabetes. The extension of the randomised ALERTT1 trial assessed the effect of switching from isCGM to rtCGM up to 24 months. Methods: In this 6-month, double-arm, parallel-group, non-masked, randomised, controlled trial, done across six hospitals in Belgium, 254 adults aged 18 years or older with type 1 diabetes previously using isCGM were randomly assigned (1:1) to rtCGM with alerts (intervention; n=127) or isCGM without alerts (control; n=127). Upon completion of the 6-month trial, the control group switched to rtCGM (is-rtCGM group), and the intervention group continued rtCGM (rt-rtCGM group). The extension focused on within-group changes in time in range (TIR; 3·9–10·0 mmol/L; primary outcome), HbA1c, time in clinically significant hypoglycaemia (<3·0 mmol/L), and Hypoglycaemia Fear Survey worry (HFS-worry) score (all prespecified key secondary outcomes). Mean within-group change versus the start of rtCGM is reported, with a positive value referring to a lower value at start of rtCGM. This trial is registered at ClinicalTrials.gov (NCT03772600 ). Findings: 119 participants were assigned to the is-rtCGM group ofSummary: Background: Comparing Continuous With Flash Glucose Monitoring In Adults With Type 1 Diabetes (ALERTT1) examined whether switching from first-generation intermittently scanned continuous glucose monitoring (isCGM) without alerts to real-time continuous glucose monitoring (rtCGM) with alert functionality offers additional benefits to adults with type 1 diabetes. The extension of the randomised ALERTT1 trial assessed the effect of switching from isCGM to rtCGM up to 24 months. Methods: In this 6-month, double-arm, parallel-group, non-masked, randomised, controlled trial, done across six hospitals in Belgium, 254 adults aged 18 years or older with type 1 diabetes previously using isCGM were randomly assigned (1:1) to rtCGM with alerts (intervention; n=127) or isCGM without alerts (control; n=127). Upon completion of the 6-month trial, the control group switched to rtCGM (is-rtCGM group), and the intervention group continued rtCGM (rt-rtCGM group). The extension focused on within-group changes in time in range (TIR; 3·9–10·0 mmol/L; primary outcome), HbA1c, time in clinically significant hypoglycaemia (<3·0 mmol/L), and Hypoglycaemia Fear Survey worry (HFS-worry) score (all prespecified key secondary outcomes). Mean within-group change versus the start of rtCGM is reported, with a positive value referring to a lower value at start of rtCGM. This trial is registered at ClinicalTrials.gov (NCT03772600 ). Findings: 119 participants were assigned to the is-rtCGM group of whom 112 (94%) completed the 24-month trial, and 123 participants were assigned to the rt-rtCGM group of whom 117 (95%) completed the 24-month trial. TIR increased from 51·8% (95% CI 49·1–54·5) at start of rtCGM (month 6) to 63·5% (60·7–66·3) at month 12 in the is-rtCGM group, and remained stable up to month 24 (change 11·7 percentage points [pp] [9·4–14·0; p<0·0001). In the rt-rtCGM group, TIR increased from 52·5% (95% CI 49·8–55·1) at start of rtCGM (month 0) to 63·0% (60·3–65·8) at month 12, also remaining stable up to month 24 (change 10·5 pp [8·2–12·8]; p<0·0001). HbA1c decreased from 7·4% (57 mmol/mol; month 6) to 6·9% (52 mmol/mol) at month 24 (change –0·54 pp [95% CI –0·64 to –0·44]; –5 mmol/mol [95% CI –6 to –4]; p<0·0001) in the is-rtCGM group, and from 7·4% (57 mmol/mol; month 0) to 7·0% (53 mmol/mol) at month 24 (change –0·43 pp [95% CI –0·53 to –0·33]; –4 mmol/mol [95% CI –5 to –3]; p<0·0001) in the rt-rtCGM group. The change in HFS-worry score was –2·67 (month 24 vs month 6; p=0·0008) in the is-rtCGM group and –5·17 points (month 24 vs month 0; p<0·0001) in the rt-rtCGM group. Time in clinically significant hypoglycaemia was unchanged in both groups after month 12. Severe hypoglycaemia decreased from 31·0 to 3·3 per 100 patient-years after switching to rtCGM. Interpretation: Glycaemic control and hypoglycaemia worry improved significantly up to 24 months after switching from isCGM without alerts to rtCGM with alerts, supporting the use of rtCGM in the care of adults with type 1 diabetes. Funding: Dexcom. … (more)
- Is Part Of:
- Lancet. Volume 11:Issue 2(2023)
- Journal:
- Lancet
- Issue:
- Volume 11:Issue 2(2023)
- Issue Display:
- Volume 11, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2023-0011-0002-0000
- Page Start:
- 96
- Page End:
- 108
- Publication Date:
- 2023-02
- Subjects:
- Diabetes -- Periodicals
Endocrinology -- Periodicals
Endocrine glands -- Diseases -- Periodicals
616.4 - Journal URLs:
- http://www.sciencedirect.com/ ↗
- DOI:
- 10.1016/S2213-8587(22)00352-7 ↗
- Languages:
- English
- ISSNs:
- 2213-8587
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.080050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25332.xml