Measurable Thoracic Motion Remains at 1 Year Following Anterior Vertebral Body Tethering, with Sagittal Motion Greater Than Coronal Motion. (15th December 2021)
- Record Type:
- Journal Article
- Title:
- Measurable Thoracic Motion Remains at 1 Year Following Anterior Vertebral Body Tethering, with Sagittal Motion Greater Than Coronal Motion. (15th December 2021)
- Main Title:
- Measurable Thoracic Motion Remains at 1 Year Following Anterior Vertebral Body Tethering, with Sagittal Motion Greater Than Coronal Motion
- Authors:
- Buyuk, Abdul Fettah
Milbrandt, Todd A.
Mathew, Smitha E.
Larson, A. Noelle - Abstract:
- Abstract : Background: Anterior vertebral body tethering is an alternative to fusion surgery for the treatment of adolescent idiopathic scoliosis (AIS) that is purported to preserve spinal motion. There is limited information regarding the measurable motion that is maintained over the instrumented levels following thoracic anterior vertebral body tethering surgery in humans. The purpose of the present study was to assess radiographic spinal motion 1 year after anterior vertebral body tethering. Methods: As part of a prospective U.S. Food and Drug Administration investigational device exemption study, 32 patients were treated with thoracic anterior vertebral body tethering. At 1 year postoperatively, patients were evaluated with standing flexion-extension and side-bending radiographs in a microdose biplanar slot scanning imaging system. The angle subtended by the screws at the upper instrumented vertebra (UIV) and lower instrumented vertebra (LIV) was measured on left and right-bending radiographs to evaluate the coronal arc of motion and was compared with preoperative values over the same levels. At 1 year postoperatively, the sagittal Cobb angle was measured over the instrumented levels on flexion and extension radiographs. Results: Side-bending radiographs revealed that the mean angle subtended by the screws changed from 15° ± 8° on left-bending radiographs to 8° ± 6° on right-bending radiographs. The mean coronal arc of motion on bending was 7° ± 6°, with 20 (62.5%) of 32Abstract : Background: Anterior vertebral body tethering is an alternative to fusion surgery for the treatment of adolescent idiopathic scoliosis (AIS) that is purported to preserve spinal motion. There is limited information regarding the measurable motion that is maintained over the instrumented levels following thoracic anterior vertebral body tethering surgery in humans. The purpose of the present study was to assess radiographic spinal motion 1 year after anterior vertebral body tethering. Methods: As part of a prospective U.S. Food and Drug Administration investigational device exemption study, 32 patients were treated with thoracic anterior vertebral body tethering. At 1 year postoperatively, patients were evaluated with standing flexion-extension and side-bending radiographs in a microdose biplanar slot scanning imaging system. The angle subtended by the screws at the upper instrumented vertebra (UIV) and lower instrumented vertebra (LIV) was measured on left and right-bending radiographs to evaluate the coronal arc of motion and was compared with preoperative values over the same levels. At 1 year postoperatively, the sagittal Cobb angle was measured over the instrumented levels on flexion and extension radiographs. Results: Side-bending radiographs revealed that the mean angle subtended by the screws changed from 15° ± 8° on left-bending radiographs to 8° ± 6° on right-bending radiographs. The mean coronal arc of motion on bending was 7° ± 6°, with 20 (62.5%) of 32 patients having a coronal arc of motion of >5°. The mean preoperative coronal arc of motion over the instrumented segments was 30° ± 9°. On flexion-extension lateral radiographs made at 1 year postoperatively, the mean kyphotic angle over the instrumented segments was 33° ± 13° in flexion and 11° ± 14° in extension, for a mean postoperative arc of motion of 21° ± 12° between flexion and extension radiographs. Conclusions: At 1 year following thoracic anterior vertebral body tethering for the treatment of AIS, the thoracic spine showed a measurable range of coronal and sagittal plane motion over the instrumented levels without evidence of complete autofusion. Motion in the coronal plane decreased by 77% following anterior vertebral body tethering. These findings provide proof of concept that sagittal spinal motion is preserved after thoracic anterior vertebral body tethering, although the functional importance remains to be determined. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 103:Number 24(2021)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 103:Number 24(2021)
- Issue Display:
- Volume 103, Issue 24 (2021)
- Year:
- 2021
- Volume:
- 103
- Issue:
- 24
- Issue Sort Value:
- 2021-0103-0024-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-15
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.20.01533 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25322.xml