Analytical Performances of an Enzymatic Assay for the Measurement of Glycated Albumin. (1st September 2016)
- Record Type:
- Journal Article
- Title:
- Analytical Performances of an Enzymatic Assay for the Measurement of Glycated Albumin. (1st September 2016)
- Main Title:
- Analytical Performances of an Enzymatic Assay for the Measurement of Glycated Albumin
- Authors:
- Testa, Roberto
Guerra, Elena
Bonfigli, Anna Rita
Di Gaetano, Nicola
Santini, Gabriele
Ceriotti, Ferruccio - Abstract:
- Abstract: Background: Short to intermediate integrated glycemic control is best determined by glycated albumin (GA). This assay is appropriate when interpretation of glycated hemoglobin (HbA1c ) is critical because of hemoglobinopathies, severe anemias, or other factors that affect red blood lifespan as hemodialysis. We evaluated a new assay based on the enzymatic quantification of GA by ketoamine oxidase and an albumin-specific protease. Methods: Limits of blank, detection, and quantification; precision; linearity; accuracy; interferences; correlation with HbA1c ; and serum vs plasma study have been evaluated on ILab ® systems. Results: Limit of blank, detection, and quantification for GA (g/L) were, respectively, 0.26, 0.36, and 1.15. Repeatability and within-device precision CVs were lower than 2.11%, 1.61%, and 1.56% for GA (g/L), albumin (g/L), and GA%, respectively. Linearity for GA (g/L) and GA% was 1.2–36.8 and 5.5–92.2, respectively. Highest deviation from linearity was <11% and recovery was higher than 90%. Accuracy against the certified ReCCS Japan Clinical Chemistry Reference Material (JCCRM) 611 was <1%. Classical interfering substances had no significant impact. Correlation of GA% between ILab ® Taurus and ADVIA system was y = 1.02[GA%]+0.25; R 2 = 0.994. No difference was found in the determination of GA% in serum vs plasma. Conclusions: GA enzymatic assay is a reliable, fully automated method allowing accurate and precise determination of GA in a routineAbstract: Background: Short to intermediate integrated glycemic control is best determined by glycated albumin (GA). This assay is appropriate when interpretation of glycated hemoglobin (HbA1c ) is critical because of hemoglobinopathies, severe anemias, or other factors that affect red blood lifespan as hemodialysis. We evaluated a new assay based on the enzymatic quantification of GA by ketoamine oxidase and an albumin-specific protease. Methods: Limits of blank, detection, and quantification; precision; linearity; accuracy; interferences; correlation with HbA1c ; and serum vs plasma study have been evaluated on ILab ® systems. Results: Limit of blank, detection, and quantification for GA (g/L) were, respectively, 0.26, 0.36, and 1.15. Repeatability and within-device precision CVs were lower than 2.11%, 1.61%, and 1.56% for GA (g/L), albumin (g/L), and GA%, respectively. Linearity for GA (g/L) and GA% was 1.2–36.8 and 5.5–92.2, respectively. Highest deviation from linearity was <11% and recovery was higher than 90%. Accuracy against the certified ReCCS Japan Clinical Chemistry Reference Material (JCCRM) 611 was <1%. Classical interfering substances had no significant impact. Correlation of GA% between ILab ® Taurus and ADVIA system was y = 1.02[GA%]+0.25; R 2 = 0.994. No difference was found in the determination of GA% in serum vs plasma. Conclusions: GA enzymatic assay is a reliable, fully automated method allowing accurate and precise determination of GA in a routine laboratory. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 1:Number 2(2016)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 1:Number 2(2016)
- Issue Display:
- Volume 1, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 1
- Issue:
- 2
- Issue Sort Value:
- 2016-0001-0002-0000
- Page Start:
- 162
- Page End:
- 171
- Publication Date:
- 2016-09-01
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2016.020446 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: