Enhancing the sensitivity for weak radioactive source detection. (January 2022)
- Record Type:
- Journal Article
- Title:
- Enhancing the sensitivity for weak radioactive source detection. (January 2022)
- Main Title:
- Enhancing the sensitivity for weak radioactive source detection
- Authors:
- Zhang, Hongjun
Wen, Ji
Mo, Zhaohong
Li, Chenguang
Wang, Xiaodong
Ren, Zhongguo
Xiong, Zhonghua
Bai, Huaiyong
Shuai, Maobing - Abstract:
- Abstract: Considering the difficulties of the low signal-to-noise ratio in weak radioactive source detections, this study proposes an abandon Gaussian tails method based on the analysis of the characteristic information denoted by the full-energy peak of the gamma spectrum of a gamma-emitting radioactive source. Based on the study of the signal-to-background ratio and the statistical fluctuations in the signal of the weak radioactive source, a factor ζ, incorporating the statistical fluctuations of signal and background and the signal-to-background ratio, is suggested to characterize the sensitivity of a radioactive source detection. When ζ reaches its maximum value, the optimal counting window around the centroid of the full-energy peak can be obtained. To evaluate the effectiveness of the proposed approach, comparisons between the proposed abandon Gaussian tails, the conventional full-energy counting, and other experiential methods were performed. The results show that the sensitivity can be significantly improved. Further, experiments with different intensity of radiation sources and duplicated experiments were conducted to examine the stability of the proposed method. Highlights: A method to enhance the sensitivity for weak radioactive source detection is presented. A factor, ζ, is suggested for characterizing the sensitivity of the presence of a radioactive source. The detection sensitivity of the source search can be improved when the factor ζ is at its maximized value.
- Is Part Of:
- Applied radiation and isotopes. Volume 179(2022)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 179(2022)
- Issue Display:
- Volume 179, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 179
- Issue:
- 2022
- Issue Sort Value:
- 2022-0179-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- Radioactive source detection -- Signal-to-noise ratio (SNR) -- Signal-to-backgound ratio -- γ-ray spectrum
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2021.109949 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25329.xml