Calibration of the underground muon detector of the Pierre Auger Observatory. (6th April 2021)
- Record Type:
- Journal Article
- Title:
- Calibration of the underground muon detector of the Pierre Auger Observatory. (6th April 2021)
- Main Title:
- Calibration of the underground muon detector of the Pierre Auger Observatory
- Authors:
- Aab, A.
Abreu, P.
Aglietta, M.
Albury, J.M.
Allekotte, I.
Almela, A.
Alvarez-Muñiz, J.
Alves Batista, R.
Anastasi, G.A.
Anchordoqui, L.
Andrada, B.
Andringa, S.
Aramo, C.
Araújo Ferreira, P.R.
Arteaga Velázquez, J.C.
Asorey, H.
Assis, P.
Avila, G.
Badescu, A.M.
Bakalova, A.
Balaceanu, A.
Barbato, F.
Barreira Luz, R.J.
Becker, K.H.
Bellido, J.A.
Berat, C.
Bertaina, M.E.
Bertou, X.
Biermann, P.L.
Bister, T.
Biteau, J.
Blazek, J.
Bleve, C.
Boháčová, M.
Boncioli, D.
Bonifazi, C.
Bonneau Arbeletche, L.
Borodai, N.
Botti, A.M.
Brack, J.
Bretz, T.
Brichetto Orchera, P.G.
Briechle, F.L.
Buchholz, P.
Bueno, A.
Buitink, S.
Buscemi, M.
Caballero-Mora, K.S.
Caccianiga, L.
Canfora, F.
Caracas, I.
Carceller, J.M.
Caruso, R.
Castellina, A.
Catalani, F.
Cataldi, G.
Cazon, L.
Cerda, M.
Chinellato, J.A.
Choi, K.
Chudoba, J.
Chytka, L.
Clay, R.W.
Cobos Cerutti, A.C.
Colalillo, R.
Coleman, A.
Coluccia, M.R.
Conceição, R.
Condorelli, A.
Consolati, G.
Contreras, F.
Convenga, F.
Correia dos Santos, D.
Covault, C.E.
Dasso, S.
Daumiller, K.
Dawson, B.R.
Day, J.A.
de Almeida, R.M.
de Jesús, J.
de Jong, S.J.
De Mauro, G.
de Mello Neto, J.R.T.
De Mitri, I.
de Oliveira, J.
de Oliveira Franco, D.
de Palma, F.
de Souza, V.
De Vito, E.
del Río, M.
Deligny, O.
Di Matteo, A.
Dobrigkeit, C.
D'Olivo, J.C.
dos Anjos, R.C.
Dova, M.T.
Ebr, J.
Engel, R.
Epicoco, I.
Erdmann, M.
Escobar, C.O.
Etchegoyen, A.
Falcke, H.
Farmer, J.
Farrar, G.
Fauth, A.C.
Fazzini, N.
Feldbusch, F.
Fenu, F.
Fick, B.
Figueira, J.M.
Filipčič, A.
Fodran, T.
Freire, M.M.
Fujii, T.
Fuster, A.
Galea, C.
Galelli, C.
García, B.
Garcia Vegas, A.L.
Gemmeke, H.
Gesualdi, F.
Gherghel-Lascu, A.
Ghia, P.L.
Giaccari, U.
Giammarchi, M.
Giller, M.
Glombitza, J.
Gobbi, F.
Gollan, F.
Golup, G.
Gómez Berisso, M.
Gómez Vitale, P.F.
Gongora, J.P.
González, J.M.
González, N.
Goos, I.
Góra, D.
Gorgi, A.
Gottowik, M.
Grubb, T.D.
Guarino, F.
Guedes, G.P.
Guido, E.
Hahn, S.
Hamal, P.
Hampel, M.R.
Hansen, P.
Harari, D.
Harvey, V.M.
Haungs, A.
Hebbeker, T.
Heck, D.
Hill, G.C.
Hojvat, C.
Hörandel, J.R.
Horvath, P.
Hrabovský, M.
Huege, T.
Hulsman, J.
Insolia, A.
Isar, P.G.
Janecek, P.
Johnsen, J.A.
Jurysek, J.
Kääpä, A.
Kampert, K.H.
Keilhauer, B.
Kemp, J.
Klages, H.O.
Kleifges, M.
Kleinfeller, J.
Köpke, M.
Kunka, N.
Lago, B.L.
Lang, R.G.
Langner, N.
Leigui de Oliveira, M.A.
Lenok, V.
Letessier-Selvon, A.
Lhenry-Yvon, I.
Lo Presti, D.
Lopes, L.
López, R.
Lu, L.
Luce, Q.
Lucero, A.
Lundquist, J.P.
Machado Payeras, A.
Mancarella, G.
Mandat, D.
Manning, B.C.
Manshanden, J.
Mantsch, P.
Marafico, S.
Mariazzi, A.G.
Mariş, I.C.
Marsella, G.
Martello, D.
Martinez, H.
Martínez Bravo, O.
Mastrodicasa, M.
Mathes, H.J.
Matthews, J.
Matthiae, G.
Mayotte, E.
Mazur, P.O.
Medina-Tanco, G.
Melo, D.
Menshikov, A.
Merenda, K.-D.
Michal, S.
Micheletti, M.I.
Miramonti, L.
Mollerach, S.
Montanet, F.
Morello, C.
Mostafá, M.
Müller, A.L.
Muller, M.A.
Mulrey, K.
Mussa, R.
Muzio, M.
Namasaka, W.M.
Nasr-Esfahani, A.
Nellen, L.
Niculescu-Oglinzanu, M.
Niechciol, M.
Nitz, D.
Nosek, D.
Novotny, V.
Nožka, L.
Nucita, A.
Núñez, L.A.
Palatka, M.
Pallotta, J.
Papenbreer, P.
Parente, G.
Parra, A.
Pech, M.
Pedreira, F.
Pȩkala, J.
Pelayo, R.
Peña-Rodriguez, J.
Pereira Martins, E.E.
Perez Armand, J.
Pérez Bertolli, C.
Perlin, M.
Perrone, L.
Petrera, S.
Pierog, T.
Pimenta, M.
Pirronello, V.
Platino, M.
Pont, B.
Pothast, M.
Privitera, P.
Prouza, M.
Puyleart, A.
Querchfeld, S.
Rautenberg, J.
Ravignani, D.
Reininghaus, M.
Ridky, J.
Riehn, F.
Risse, M.
Rizi, V.
Rodrigues de Carvalho, W.
Rodriguez Rojo, J.
Roncoroni, M.J.
Roth, M.
Roulet, E.
Rovero, A.C.
Ruehl, P.
Saffi, S.J.
Saftoiu, A.
Salamida, F.
Salazar, H.
Salina, G.
Sanabria Gomez, J.D.
Sánchez, F.
Santos, E.M.
Santos, E.
Sarazin, F.
Sarmento, R.
Sarmiento-Cano, C.
Sato, R.
Savina, P.
Schäfer, C.M.
Scherini, V.
Schieler, H.
Schimassek, M.
Schimp, M.
Schlüter, F.
Schmidt, D.
Scholten, O.
Schovánek, P.
Schröder, F.G.
Schröder, S.
Schulte, J.
Sciutto, S.J.
Scornavacche, M.
Segreto, A.
Sehgal, S.
Shellard, R.C.
Sigl, G.
Silli, G.
Sima, O.
Šmída, R.
Sommers, P.
Soriano, J.F.
Souchard, J.
Squartini, R.
Stadelmaier, M.
Stanca, D.
Stanič, S.
Stasielak, J.
Stassi, P.
Streich, A.
Suárez-Durán, M.
Sudholz, T.
Suomijärvi, T.
Supanitsky, A.D.
Šupík, J.
Szadkowski, Z.
Taboada, A.
Tapia, A.
Taricco, C.
Timmermans, C.
Tkachenko, O.
Tobiska, P.
Todero Peixoto, C.J.
Tomé, B.
Travaini, A.
Travnicek, P.
Trimarelli, C.
Trini, M.
Tueros, M.
Ulrich, R.
Unger, M.
Vaclavek, L.
Vacula, M.
Valdés Galicia, J.F.
Valore, L.
Varela, E.
Varma K.C., V.
Vásquez-Ramírez, A.
Veberič, D.
Ventura, C.
Vergara Quispe, I.D.
Verzi, V.
Vicha, J.
Vink, J.
Vorobiov, S.
Wahlberg, H.
Watanabe, C.
Watson, A.A.
Weber, M.
Weindl, A.
Wiencke, L.
Wilczyński, H.
Winchen, T.
Wirtz, M.
Wittkowski, D.
Wundheiler, B.
Yushkov, A.
Zapparrata, O.
Zas, E.
Zavrtanik, D.
Zavrtanik, M.
Zehrer, L.
Zepeda, A.
… (more) - Other Names:
- collab.
- Abstract:
- Abstract: To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changingAbstract: To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years. … (more)
- Is Part Of:
- Journal of instrumentation. Volume 16:Number 4(2021)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 16:Number 4(2021)
- Issue Display:
- Volume 16, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 16
- Issue:
- 4
- Issue Sort Value:
- 2021-0016-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-06
- Subjects:
- Particle detectors -- Detector alignment and calibration methods (lasers, sources, particle-beams) -- Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc) -- Performance of High Energy Physics Detectors
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/16/04/P04003 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25292.xml