IDEAL Stage 2a experience with in-office, transperineal MRI/ultrasound software fusion targeted prostate biopsy. Issue 1 (21st November 2019)
- Record Type:
- Journal Article
- Title:
- IDEAL Stage 2a experience with in-office, transperineal MRI/ultrasound software fusion targeted prostate biopsy. Issue 1 (21st November 2019)
- Main Title:
- IDEAL Stage 2a experience with in-office, transperineal MRI/ultrasound software fusion targeted prostate biopsy
- Authors:
- Tzeng, Michael
Cricco-Lizza, Eliza
Al Hussein Al Awamlh, Bashir
Pantuck, Morgan
Margolis, Daniel J
Yu, Miko
Hu, Jim - Abstract:
- Abstract : Objective: Although the feasibility of transperineal biopsy under local anesthesia has been demonstrated, little is known regarding the application of MRI/ultrasound software fusion targeted biopsy for transperineal biopsy under local anesthesia. The objective of our study is to describe our initial experience with in-office transperineal MRI/ultrasound software fusion targeted biopsy (Idea, Development, Exploration, Assessment, Long-term Follow-up [IDEAL] Stage 2a). Methods: Between October 2017 and July 2019, 33 men underwent in-office transperineal MRI-targeted biopsy using the Artemis (Eigen, Grass Valley, CA, USA) fixed-robotic arm system. The indication for biopsy was elevated prostate specific antigen (PSA) (n=14), prior negative biopsy (n=10), active surveillance (n=6), and surveillance after partial gland cryoablation (n=3). We prospectively captured patient demographic and clinical characteristics, biopsy outcomes, and complications. Complications were classified according to Common Terminology Criteria for Adverse Events (CTCAE) V.5.0. Results: The median patient age was 67 years (IQR 61–71) and the median serum PSA level was 7.0 ng/mL (IQR 5.1–11.4). The median duration of in-office MRI-targeted transperineal biopsy was 26 min (IQR 23–28). Overall, transperineal MRI-targeted biopsy detected prostate cancer in 18 (54.6%) men, with 8 (24.2%) being clinically significant (Gleason Score ≥3+4, Grade Group ≥2). Clinically significant prostate cancer wasAbstract : Objective: Although the feasibility of transperineal biopsy under local anesthesia has been demonstrated, little is known regarding the application of MRI/ultrasound software fusion targeted biopsy for transperineal biopsy under local anesthesia. The objective of our study is to describe our initial experience with in-office transperineal MRI/ultrasound software fusion targeted biopsy (Idea, Development, Exploration, Assessment, Long-term Follow-up [IDEAL] Stage 2a). Methods: Between October 2017 and July 2019, 33 men underwent in-office transperineal MRI-targeted biopsy using the Artemis (Eigen, Grass Valley, CA, USA) fixed-robotic arm system. The indication for biopsy was elevated prostate specific antigen (PSA) (n=14), prior negative biopsy (n=10), active surveillance (n=6), and surveillance after partial gland cryoablation (n=3). We prospectively captured patient demographic and clinical characteristics, biopsy outcomes, and complications. Complications were classified according to Common Terminology Criteria for Adverse Events (CTCAE) V.5.0. Results: The median patient age was 67 years (IQR 61–71) and the median serum PSA level was 7.0 ng/mL (IQR 5.1–11.4). The median duration of in-office MRI-targeted transperineal biopsy was 26 min (IQR 23–28). Overall, transperineal MRI-targeted biopsy detected prostate cancer in 18 (54.6%) men, with 8 (24.2%) being clinically significant (Gleason Score ≥3+4, Grade Group ≥2). Clinically significant prostate cancer was detected in four (28.6%) biopsy naïve men, two (20.0%) men with a prior negative, one (16.7%) man on active surveillance and one (33.3%) man following partial gland ablation. Three (9.1%) men experienced complications: two hematuria and one urinary retention. Conclusion: Our findings demonstrate the feasibility of the fixed-robotic arm fusion platform for in-office transperineal MRI-targeted biopsy and a low rate of adverse events. However, larger prostate size precludes MRI/ultrasound software fusion and pubic arch interference hindered the transperineal MRI-targeted approach in 9.1% of men. Pubic arch interference was overcome by a free-hand approach with software fusion guidance. … (more)
- Is Part Of:
- BMJ surgery, interventions, & health technologies. Volume 1:Issue 1(2019)
- Journal:
- BMJ surgery, interventions, & health technologies
- Issue:
- Volume 1:Issue 1(2019)
- Issue Display:
- Volume 1, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 1
- Issue:
- 1
- Issue Sort Value:
- 2019-0001-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11-21
- Subjects:
- MRI -- software fusion -- transperineal -- prostate biopsy
Surgery -- Periodicals
Surgery -- Research -- Periodicals
Medical care -- Periodicals
Medical care -- Research -- Periodicals
617.005 - Journal URLs:
- http://www.bmj.com/archive ↗
- DOI:
- 10.1136/bmjsit-2019-000025 ↗
- Languages:
- English
- ISSNs:
- 2631-4940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25278.xml