CT imaging prior to transcatheter aortic valve implantation in the UK. Issue 1 (6th April 2020)
- Record Type:
- Journal Article
- Title:
- CT imaging prior to transcatheter aortic valve implantation in the UK. Issue 1 (6th April 2020)
- Main Title:
- CT imaging prior to transcatheter aortic valve implantation in the UK
- Authors:
- Harries, Iwan
Weir-McCall, Jonathan R
Williams, Michelle C
Shambrook, James
Roditi, Giles
Bull, Russel
Morgan-Hughes, Gareth J
Nicol, Edward D
Moss, Alastair J - Abstract:
- Abstract : Objective: This cross-sectional observational study sought to describe variations in CT in the context of transcatheter aortic valve implantation (CT-TAVI) as currently performed in the UK. Methods: 408 members of the British Society of Cardiovascular Imaging were invited to complete a 27-item online CT-TAVI survey. Results: 47 responses (12% response rate) were received from 40 cardiac centres, 23 (58%) of which performed TAVI on-site (TAVI centres). Only six respondents (13%) performed high-volume activity (>200 scans per year) compared with 13 (28%) performing moderate (100–200 scans per year) and 27 (59%) performing low (0–99 scans per year) volume activity. Acquisition protocols varied (41% retrospective, 12% prospective with wide padding, 47% prospective with narrow padding), as did the phase of reporting (45% systolic, 37% diastolic, 11% both, 6% unreported). Median dose length product was 675 mGy.cm (IQR 477–954 mGy.cm). Compared with non-TAVI centres, TAVI centres were more likely to report minimum iliofemoral luminal diameter (n=25, 96% vs n=7, 58%, p=0.003) and optimal tube angulation for intervention (n=12, 46% vs n=1, 8%, p=0.02). Conclusions: This national survey formally describes current CT-TAVI practice in the UK. High-volume activity was only present at one in seven cardiac CT centres. There is wide variation in scan acquisition, scan reporting and radiation dose exposure in cardiac CT centres.
- Is Part Of:
- Open heart. Volume 7:Issue 1(2020)
- Journal:
- Open heart
- Issue:
- Volume 7:Issue 1(2020)
- Issue Display:
- Volume 7, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2020-0007-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04-06
- Subjects:
- CT scanning -- percutaneous valve therapy -- aortic valve disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Patients -- Periodicals
616.12005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://openheart.bmj.com/ ↗ - DOI:
- 10.1136/openhrt-2019-001233 ↗
- Languages:
- English
- ISSNs:
- 2398-595X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25244.xml